Plastic vs. glass: the effect of the synthetic material in contact with DMEK tissue during staining on endothelial cell loss
摘要
Endothelial cell loss (ECL) during Descemet membrane endothelial keratoplasty (DMEK) graft preparation has been shown to affect graft survival and the need for re-grafting. The purpose of this study was to quantitatively assess the impact of the plastic and glass mediums in contact with DMEK donor tissue during intra-operative graft staining on ECL.
MethodsRetrospective study that included patients who underwent DMEK surgery between January 2019 and June 2021 at Hôpital Maisonneuve-Rosemont and the Jewish General Hospital in Montreal, Canada. DMEK grafts were stained with 0.06% Trypan blue ophthalmic solution (VisionBlue®, Dutch Ophthalmic, USA, Exeter, NH) for 120 s in either a plastic or glass medium prior to delivery into the recipient’s eye. The ECL was compared between the two groups 12–30 months post-operatively.
ResultsECL at 12–30 months was significantly less in the eyes that had received grafts stained in a plastic medium compared to those stained in a glass medium. Graft survival and re-bubbling was higher in the glass group however this difference was not statistically significant.
ConclusionStaining of the DMEK graft in a plastic medium caused less ECL compared to the glass medium.