错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Plastic vs. glass: the effect of the synthetic material in contact with DMEK tissue during staining on endothelial cell loss

  • Abdullah Al-Kaabi,
  • Britta Gustavson,
  • Abdulrahman Alotaibi,
  • Ayman Aljohani,
  • Julia Talajic,
  • Johanna Choremis

摘要

Purpose

Endothelial cell loss (ECL) during Descemet membrane endothelial keratoplasty (DMEK) graft preparation has been shown to affect graft survival and the need for re-grafting. The purpose of this study was to quantitatively assess the impact of the plastic and glass mediums in contact with DMEK donor tissue during intra-operative graft staining on ECL.

Methods

Retrospective study that included patients who underwent DMEK surgery between January 2019 and June 2021 at Hôpital Maisonneuve-Rosemont and the Jewish General Hospital in Montreal, Canada. DMEK grafts were stained with 0.06% Trypan blue ophthalmic solution (VisionBlue®, Dutch Ophthalmic, USA, Exeter, NH) for 120 s in either a plastic or glass medium prior to delivery into the recipient’s eye. The ECL was compared between the two groups 12–30 months post-operatively.

Results

ECL at 12–30 months was significantly less in the eyes that had received grafts stained in a plastic medium compared to those stained in a glass medium. Graft survival and re-bubbling was higher in the glass group however this difference was not statistically significant.

Conclusion

Staining of the DMEK graft in a plastic medium caused less ECL compared to the glass medium.