错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Diagnosis of retinal damage using Resnet rescaling and support vector machine (Resnet-RS-SVM): a case study from an Indian hospital

  • Santi Kumari Behera,
  • Rina Mahakud,
  • Millee Panigrahi,
  • Prabira Kumar Sethy,
  • Rasmikanta Pati

摘要

Purpose

This study aims to address the challenge of identifying retinal damage in medical applications through a computer-aided diagnosis (CAD) approach. Data was collected from four prominent eye hospitals in India for analysis and model development.

Methods

Data was collected from Silchar Medical College and Hospital (SMCH), Aravind Eye Hospital (Tamil Nadu), LV Prasad Eye Hospital (Hyderabad), and Medanta (Gurugram). A modified version of the ResNet-101 architecture, named ResNet-RS, was utilized for retinal damage identification. In this modified architecture, the last layer's softmax function was replaced with a support vector machine (SVM). The resulting model, termed ResNet-RS-SVM, was trained and evaluated on each hospital's dataset individually and collectively.

Results

The proposed ResNet-RS-SVM model achieved high accuracies across the datasets from the different hospitals: 99.17% for Aravind, 98.53% for LV Prasad, 98.33% for Medanta, and 100% for SMCH. When considering all hospitals collectively, the model attained an accuracy of 97.19%.

Conclusion

The findings demonstrate the effectiveness of the ResNet-RS-SVM model in accurately identifying retinal damage in diverse datasets collected from multiple eye hospitals in India. This approach presents a promising advancement in computer-aided diagnosis for improving the detection and management of retinal diseases.