<p>Structure hardening is a key strategy to help mitigate building destruction during wildland-urban interface fires. Windows represent an important vulnerability for structure failure by allowing heat transfer to interior combustibles, and in cases of mechanical failure, an entry point for flames and/or embers. The purpose of this study is to characterize heat transfer through windows with various common construction variables (plain (annealed) versus tempered glass, single- versus double-pane, low-emissivity coating versus no coating, and air-filled versus argon-filled pane gap). Small-scale experiments were performed with 23&#xa0;cm by 23&#xa0;cm windows exposed to a radiant panel producing centerpoint incident heat fluxes of 10&#xa0;<InlineEquation ID="IEq1"> <InlineMediaObject> <ImageObject Color="BlackWhite" FileRef="10694_2024_1685_Article_IEq1.gif" Format="GIF" Height="22" Rendition="HTML" Resolution="72" Type="Linedraw" Width="53" /> </InlineMediaObject> <EquationSource Format="TEX">\(\hbox {kW/m}^{2}\)</EquationSource> <EquationSource Format="MATHML"><math> <msup> <mtext>kW/m</mtext> <mn>2</mn> </msup> </math></EquationSource> </InlineEquation>, 20&#xa0;<InlineEquation ID="IEq2"> <InlineMediaObject> <ImageObject Color="BlackWhite" FileRef="10694_2024_1685_Article_IEq1.gif" Format="GIF" Height="22" Rendition="HTML" Resolution="72" Type="Linedraw" Width="53" /> </InlineMediaObject> <EquationSource Format="TEX">\(\hbox {kW/m}^{2}\)</EquationSource> <EquationSource Format="MATHML"><math> <msup> <mtext>kW/m</mtext> <mn>2</mn> </msup> </math></EquationSource> </InlineEquation>, 30&#xa0;<InlineEquation ID="IEq3"> <InlineMediaObject> <ImageObject Color="BlackWhite" FileRef="10694_2024_1685_Article_IEq1.gif" Format="GIF" Height="22" Rendition="HTML" Resolution="72" Type="Linedraw" Width="53" /> </InlineMediaObject> <EquationSource Format="TEX">\(\hbox {kW/m}^{2}\)</EquationSource> <EquationSource Format="MATHML"><math> <msup> <mtext>kW/m</mtext> <mn>2</mn> </msup> </math></EquationSource> </InlineEquation>, 40&#xa0;<InlineEquation ID="IEq4"> <InlineMediaObject> <ImageObject Color="BlackWhite" FileRef="10694_2024_1685_Article_IEq1.gif" Format="GIF" Height="22" Rendition="HTML" Resolution="72" Type="Linedraw" Width="53" /> </InlineMediaObject> <EquationSource Format="TEX">\(\hbox {kW/m}^{2}\)</EquationSource> <EquationSource Format="MATHML"><math> <msup> <mtext>kW/m</mtext> <mn>2</mn> </msup> </math></EquationSource> </InlineEquation>, and 50&#xa0;<InlineEquation ID="IEq5"> <InlineMediaObject> <ImageObject Color="BlackWhite" FileRef="10694_2024_1685_Article_IEq1.gif" Format="GIF" Height="22" Rendition="HTML" Resolution="72" Type="Linedraw" Width="53" /> </InlineMediaObject> <EquationSource Format="TEX">\(\hbox {kW/m}^{2}\)</EquationSource> <EquationSource Format="MATHML"><math> <msup> <mtext>kW/m</mtext> <mn>2</mn> </msup> </math></EquationSource> </InlineEquation>. Total heat flux was measured 5.1&#xa0;cm behind the window glass. Times of pane cracking and other failure events were recorded. Double-pane designs reduced heat transfer through a window more than the single-pane design (measured 13% to 43% and 39% to 60% of the incident heat flux, respectively). Heat transfer was further reduced when a low-emissivity coating was present (measured 5 to 14% of the incident heat flux). The differences in measured heat flux behind plain glass versus tempered glass windows and air-filled versus argon-filled windows were not statistically significant. Tempered glass performed better than plain glass, and double-pane argon-filled windows consistently survived longer than double-pane air-filled windows. In some cases, heat fluxes measured behind the windows surpassed the critical heat flux required for ignition of some common household combustibles.</p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Experimental Study of Heat Transfer Through Windows Exposed to a Radiant Panel Heater

  • Rebekah L. Schrader,
  • Shuna Ni,
  • Nicholas W. Dow,
  • Joseph M. Willi,
  • Matthew J. DiDomizio,
  • Gavin P. Horn

摘要

Structure hardening is a key strategy to help mitigate building destruction during wildland-urban interface fires. Windows represent an important vulnerability for structure failure by allowing heat transfer to interior combustibles, and in cases of mechanical failure, an entry point for flames and/or embers. The purpose of this study is to characterize heat transfer through windows with various common construction variables (plain (annealed) versus tempered glass, single- versus double-pane, low-emissivity coating versus no coating, and air-filled versus argon-filled pane gap). Small-scale experiments were performed with 23 cm by 23 cm windows exposed to a radiant panel producing centerpoint incident heat fluxes of 10  \(\hbox {kW/m}^{2}\) kW/m 2 , 20  \(\hbox {kW/m}^{2}\) kW/m 2 , 30  \(\hbox {kW/m}^{2}\) kW/m 2 , 40  \(\hbox {kW/m}^{2}\) kW/m 2 , and 50  \(\hbox {kW/m}^{2}\) kW/m 2 . Total heat flux was measured 5.1 cm behind the window glass. Times of pane cracking and other failure events were recorded. Double-pane designs reduced heat transfer through a window more than the single-pane design (measured 13% to 43% and 39% to 60% of the incident heat flux, respectively). Heat transfer was further reduced when a low-emissivity coating was present (measured 5 to 14% of the incident heat flux). The differences in measured heat flux behind plain glass versus tempered glass windows and air-filled versus argon-filled windows were not statistically significant. Tempered glass performed better than plain glass, and double-pane argon-filled windows consistently survived longer than double-pane air-filled windows. In some cases, heat fluxes measured behind the windows surpassed the critical heat flux required for ignition of some common household combustibles.