The Tube Furnace with Online Mass Loss Measurement as a New Bench Scale Test for Pyrolysis
摘要
In this paper, a new gram scale experiment with well characterised boundary conditions is proposed for pyrolysis experiments. The set-up consists of a tube furnace, based on ISO19700, with a newly designed concept for a balance within the oven, allowing for online mass loss measurements. Samples with a length up to 50 cm can be investigated in this apparatus. The oven allows for experiments at fixed temperatures or at fixed heating rates, under controlled atmosphere, w.r.t. gas composition and flow rate. A thorough characterisation of the set-up is presented, including aspects like reproducibility of the heating rate or the precision of the balance. The functionality of the balance has been demonstrated with calcium carbonate (CaCO