<p>A Digital Micromirror Device (DMD)-based Multi-Object Spectrograph (D-MOS) with an integrated imager has been developed. The optical performance of the MOS is evaluated through comprehensive laboratory calibration and on-sky observations using the 1.3-meter J.C. Bhattacharya (JCB) Telescope at the Vainu Bappu Observatory (VBO). The system is designed to assess the viability of using a DMD as a programmable slit mechanism for future ultraviolet-optical space missions. A complete imager-cum-spectrograph assembly was constructed using off-the-shelf optical components and configured for operation in the optical band, employing a DLP9500 DMD with a 1920<InlineEquation ID="IEq1"> <InlineMediaObject> <ImageObject Color="BlackWhite" FileRef="10686_2025_10024_Article_IEq1.gif" Format="GIF" Height="13" Rendition="HTML" Resolution="72" Type="Linedraw" Width="19" /> </InlineMediaObject> <EquationSource Format="TEX">\(\times\)</EquationSource> </InlineEquation>1080 micromirror array. Calibration experiments established the DMD-to-detector coordinate mapping and validated the strategies for object selection and slit placement. On-sky tests in crowded stellar fields confirmed successful slit targeting, precise object alignment, and multiplexed spectral acquisition. The spectrograph achieved a peak efficiency of 32%, a spectral resolving power of R<InlineEquation ID="IEq2"> <InlineMediaObject> <ImageObject Color="BlackWhite" FileRef="10686_2025_10024_Article_IEq2.gif" Format="GIF" Height="6" Rendition="HTML" Resolution="72" Type="Linedraw" Width="17" /> </InlineMediaObject> <EquationSource Format="TEX">\(\sim\)</EquationSource> </InlineEquation>1000 at 6000Å, a multiplexing capability of up to 46 slits (extendable to 85), and a contrast ratio of <InlineEquation ID="IEq3"> <InlineMediaObject> <ImageObject Color="BlackWhite" FileRef="10686_2025_10024_Article_IEq2.gif" Format="GIF" Height="6" Rendition="HTML" Resolution="72" Type="Linedraw" Width="17" /> </InlineMediaObject> <EquationSource Format="TEX">\(\sim\)</EquationSource> </InlineEquation> 6000. These results demonstrate the robustness and effectiveness of the DMD MOS system under real observational conditions and raise its TRL level for use in next-generation spectroscopic space missions.</p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

DMD-based Multi-Object Spectrograph (D-MOS): AIV and first light results

  • Sriram S,
  • Vineeth Valsan,
  • Remya B. S,
  • Subramaniam A,
  • Maheswar G

摘要

A Digital Micromirror Device (DMD)-based Multi-Object Spectrograph (D-MOS) with an integrated imager has been developed. The optical performance of the MOS is evaluated through comprehensive laboratory calibration and on-sky observations using the 1.3-meter J.C. Bhattacharya (JCB) Telescope at the Vainu Bappu Observatory (VBO). The system is designed to assess the viability of using a DMD as a programmable slit mechanism for future ultraviolet-optical space missions. A complete imager-cum-spectrograph assembly was constructed using off-the-shelf optical components and configured for operation in the optical band, employing a DLP9500 DMD with a 1920 \(\times\) 1080 micromirror array. Calibration experiments established the DMD-to-detector coordinate mapping and validated the strategies for object selection and slit placement. On-sky tests in crowded stellar fields confirmed successful slit targeting, precise object alignment, and multiplexed spectral acquisition. The spectrograph achieved a peak efficiency of 32%, a spectral resolving power of R \(\sim\) 1000 at 6000Å, a multiplexing capability of up to 46 slits (extendable to 85), and a contrast ratio of \(\sim\) 6000. These results demonstrate the robustness and effectiveness of the DMD MOS system under real observational conditions and raise its TRL level for use in next-generation spectroscopic space missions.