Calibration of VELC detectors on-board Aditya-L1 mission

  • Shalabh Mishra,
  • Sasikumar Raja K,
  • Sanal Krishnan VU,
  • Venkata Suresh Narra,
  • Bhavana Hegde S,
  • Utkarsha D,
  • Muthu Priyal V,
  • Pawan Kumar S,
  • Natarajan V,
  • Raghavendra Prasad B,
  • Jagdev Singh,
  • Umesh Kamath P,
  • Kathiravan S,
  • Vishnu T,
  • Suresha,
  • Savarimuthu P,
  • Jalshri H Desai,
  • Rajiv Kumaran,
  • Shiv Sagar,
  • Sumit Kumar,
  • Inderjeet Singh Bamrah,
  • Amit Kumar

摘要

Aditya-L1 is the first Indian space mission to explore the Sun and solar atmosphere with seven multi-wavelength payloads, with Visible Emission Line Coronagraph (VELC) being the prime payload. It is an internally occulted coronagraph with four channels to image the Sun at 5000 Å  in the field of view 1.05 - 3 \(\varvec{R}_{\odot }\) R , and to pursue spectroscopy at 5303 Å, 7892 Å  and 10747 Å  channels in the FOV (1.05 - 1.5 \(\varvec{R}_{\odot }\) R ). In addition, spectropolarimetry is planned at 10747 Å  channel. Therefore, VELC has three sCMOS detectors and one InGaAs detector. In this article, we aim to describe the technical details and specifications of the detectors achieved by way of thermo-vacuum calibration at the CREST campus of the Indian Institute of Astrophysics, Bangalore, India. Furthermore, we report the estimated conversion gain, full-well capacity, and readout noise at different temperatures. Based on the numbers, it is thus concluded that it is essential to operate the sCMOS detectors and InGaAs detector at \(\varvec{-5^\circ }\) - 5 and \(\varvec{-17^{\circ }}\) - 17 C, respectively, at the spacecraft level.