<p>The article describes a&#xa0;methodology justifying the serviceability of a&#xa0;nuclear power plant containment for predicting the forces in the anchors of reinforcement bundles and concluding about their performance without using hydraulic jacks and the lift-off method. The calculation methodology is based on the results of monitoring the forces in each reinforcement bundle using PSI-01 force sensors, as well as on readings from control and measuring equipment, including containment movement sensors.</p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Monitoring of forces in reinforcement bundles of nuclear power plant containments and emergency load justification

  • V. N. Medvedev,
  • A. S. Kiselev,
  • A. S. Kiselev,
  • V. F. Strizhov,
  • A. N. Ulyanov,
  • M. I. Skorikova

摘要

The article describes a methodology justifying the serviceability of a nuclear power plant containment for predicting the forces in the anchors of reinforcement bundles and concluding about their performance without using hydraulic jacks and the lift-off method. The calculation methodology is based on the results of monitoring the forces in each reinforcement bundle using PSI-01 force sensors, as well as on readings from control and measuring equipment, including containment movement sensors.