<p>Designing adsorption processes requires knowledge of the adsorption isotherms. Measuring accurate isotherms is time consuming and inefficient equidistant points are usually chosen. Here, we combine isotherm measurements with Model-Based Design of Experiments to iteratively determine isotherm models with less experimental effort, while maintaining high model accuracy. Our joint approach combining isotherm model discrimination and parameter precision is validated by thermo-gravimetric experiments for the adsorption pairs Lewatit&#xa0;VP&#xa0;OC&#xa0;1065 with <InlineEquation ID="IEq1"> <EquationSource Format="TEX">\(\textrm{CO}_2\)</EquationSource> </InlineEquation> and <InlineEquation ID="IEq2"> <EquationSource Format="TEX">\(\textrm{H}_2\textrm{O}\)</EquationSource> </InlineEquation> and BAM-P109 with <InlineEquation ID="IEq3"> <EquationSource Format="TEX">\(\textrm{H}_2\textrm{O}\)</EquationSource> </InlineEquation>, covering isotherm Types&#xa0;I, III, and&#xa0;V. Results show that the experimental effort could be reduced between&#xa0;70–81%. Furthermore, the framework scheduled measurements for Lewatit&#xa0;VP&#xa0;OC&#xa0;1065/<InlineEquation ID="IEq4"> <EquationSource Format="TEX">\(\textrm{H}_2\textrm{O}\)</EquationSource> </InlineEquation> to discriminate its isotherm Type between II or III, devoid of our bias as experimenters. Overall, our approach demonstrates potential to streamline the identification of adsorption isotherms while enabling more efficient and unbiased model development.</p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Model-based design of experiments for adsorption isotherms

  • Matthias Henninger,
  • Patrik Postweiler,
  • Mirko Engelpracht,
  • Federico Galvanin,
  • André Bardow

摘要

Designing adsorption processes requires knowledge of the adsorption isotherms. Measuring accurate isotherms is time consuming and inefficient equidistant points are usually chosen. Here, we combine isotherm measurements with Model-Based Design of Experiments to iteratively determine isotherm models with less experimental effort, while maintaining high model accuracy. Our joint approach combining isotherm model discrimination and parameter precision is validated by thermo-gravimetric experiments for the adsorption pairs Lewatit VP OC 1065 with \(\textrm{CO}_2\) and \(\textrm{H}_2\textrm{O}\) and BAM-P109 with \(\textrm{H}_2\textrm{O}\) , covering isotherm Types I, III, and V. Results show that the experimental effort could be reduced between 70–81%. Furthermore, the framework scheduled measurements for Lewatit VP OC 1065/ \(\textrm{H}_2\textrm{O}\) to discriminate its isotherm Type between II or III, devoid of our bias as experimenters. Overall, our approach demonstrates potential to streamline the identification of adsorption isotherms while enabling more efficient and unbiased model development.