Establishing the cutoff value of near visual acuity for assessment of early presbyopia

  • Akiko Hanyuda,
  • Miyuki Kubota,
  • Shunsuke Kubota,
  • Sachiko Masui,
  • Kenya Yuki,
  • Masahiko Ayaki,
  • Kazuno Negishi

摘要

Purpose

There is limited evidence to evaluate the numerical cutoff point for detecting early presbyopia. Thus, we aimed to establish a clinically relevant optimal cutoff value of near visual acuity for detecting early presbyopia.

Study design

Prospective diagnostic accuracy study.

Methods

We included consecutive individuals aged ≥ 20 years with a binocular-corrected distance visual acuity of ≥ 20/25 who did not undergo ophthalmic surgery between December 17, 2020 and December 19, 2021, at two healthcare facilities in Japan. Binocular distance-corrected near visual acuity at 40 cm, accommodative amplitude, awareness of presbyopia, and Near Activity Visual Questionnaire scores were examined. The optimal cutoff values of distance-corrected near visual acuity for diagnosing early presbyopia were evaluated using receiver operating characteristic plots.

Results

Among 115 participants, 74 (64.3%) had presbyopia. The proportion of participants with no difficulty performing near-vision tasks decreased markedly when near visual acuity decreased to 20/20 (> 0.00 logMAR). A cutoff value of 0.00 logMAR for distance-corrected near visual acuity was optimal, showing high sensitivity of 56.76% and specificity of 92.68%, as opposed to the commonly used cutoff value of 0.40 logMAR (20/50; sensitivity, 9.46% and specificity, 100%) for diagnosing early presbyopia.

Conclusion

Near visual acuity of 0.00 logMAR (20/20) could be the optimal cutoff value for diagnosing early presbyopia.