Establishing the cutoff value of near visual acuity for assessment of early presbyopia
摘要
There is limited evidence to evaluate the numerical cutoff point for detecting early presbyopia. Thus, we aimed to establish a clinically relevant optimal cutoff value of near visual acuity for detecting early presbyopia.
Study designProspective diagnostic accuracy study.
MethodsWe included consecutive individuals aged ≥ 20 years with a binocular-corrected distance visual acuity of ≥ 20/25 who did not undergo ophthalmic surgery between December 17, 2020 and December 19, 2021, at two healthcare facilities in Japan. Binocular distance-corrected near visual acuity at 40 cm, accommodative amplitude, awareness of presbyopia, and Near Activity Visual Questionnaire scores were examined. The optimal cutoff values of distance-corrected near visual acuity for diagnosing early presbyopia were evaluated using receiver operating characteristic plots.
ResultsAmong 115 participants, 74 (64.3%) had presbyopia. The proportion of participants with no difficulty performing near-vision tasks decreased markedly when near visual acuity decreased to 20/20 (> 0.00 logMAR). A cutoff value of 0.00 logMAR for distance-corrected near visual acuity was optimal, showing high sensitivity of 56.76% and specificity of 92.68%, as opposed to the commonly used cutoff value of 0.40 logMAR (20/50; sensitivity, 9.46% and specificity, 100%) for diagnosing early presbyopia.
ConclusionNear visual acuity of 0.00 logMAR (20/20) could be the optimal cutoff value for diagnosing early presbyopia.