错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Results of the 2023 ISBI challenge to reduce GABA-edited MRS acquisition time

  • Rodrigo Pommot Berto,
  • Hanna Bugler,
  • Gabriel Dias,
  • Mateus Oliveira,
  • Lucas Ueda,
  • Sergio Dertkigil,
  • Paula D. P. Costa,
  • Leticia Rittner,
  • Julian P. Merkofer,
  • Dennis M. J. van de Sande,
  • Sina Amirrajab,
  • Gerhard S. Drenthen,
  • Mitko Veta,
  • Jacobus F. A. Jansen,
  • Marcel Breeuwer,
  • Ruud J. G. van Sloun,
  • Abdul Qayyum,
  • Cristobal Rodero,
  • Steven Niederer,
  • Roberto Souza,
  • Ashley D. Harris

摘要

Purpose

Use a conference challenge format to compare machine learning-based gamma-aminobutyric acid (GABA)-edited magnetic resonance spectroscopy (MRS) reconstruction models using one-quarter of the transients typically acquired during a complete scan.

Methods

There were three tracks: Track 1: simulated data, Track 2: identical acquisition parameters with in vivo data, and Track 3: different acquisition parameters with in vivo data. The mean squared error, signal-to-noise ratio, linewidth, and a proposed shape score metric were used to quantify model performance. Challenge organizers provided open access to a baseline model, simulated noise-free data, guides for adding synthetic noise, and in vivo data.

Results

Three submissions were compared. A covariance matrix convolutional neural network model was most successful for Track 1. A vision transformer model operating on a spectrogram data representation was most successful for Tracks 2 and 3. Deep learning (DL) reconstructions with 80 transients achieved equivalent or better SNR, linewidth and fit error compared to conventional 320 transient reconstructions. However, some DL models optimized linewidth and SNR without actually improving overall spectral quality, indicating a need for more robust metrics.

Conclusion