Can standing replace upright tilt table testing in the diagnosis of postural tachycardia syndrome (POTS) in the young?

  • Julian M. Stewart,
  • Marvin S. Medow

摘要

Purpose

We compared standing and upright tilt in patients with postural tachycardia syndrome (POTS) and healthy volunteers to determine whether standing accurately tests for POTS in youngsters < 19 years. POTS in adolescents is defined by orthostatic intolerance plus sustained excessive upright tachycardia, without hypotension during upright tilt. We examined whether active standing is a valid classifier for POTS in adolescents compared to tilt.

Methods

Patients with POTS (N = 36, 12.2–18.8 years) and healthy volunteers (N = 39, 13.1–18.9 years) performed stand for a minimum of 5-min and were tilted to 70° for 10 min. Receiver operating characteristics analyses (ROC) were performed at 5-min stand, and at 5  and 10 min tilt for optimal threshold for heart rate (HR) increase (ΔHR), and test sensitivity and specificity.

Results

Most subjects were unable to stand for 10 min. ΔHRs at 5 min stand were higher in POTS (31 ± 3) compared with control (21 ± 2) and elevated at 5- or 10-min tilt in POTS (51 ± 3 and 51 ± 2) versus control (26 ± 2 and 25 ± 2) compared with standing. ΔHR in POTS and controls for 10 min were not different from 5 min. For 5 min stand ROC threshold was 26 beats per min (bpm), sensitivity of 70.6%, and specificity of 68.2% compared with 39 bpm, 88.2%, and 95.1% for 5 min tilt, and 40 bpm, 94.1%, and 95.1% for 10-min tilt. A precision-recall graph confirmed the superior discriminating ability of 5 min and 10 min tilt compared to 5 min stand.

Conclusions

The stand test is relatively non-specific and imprecise compared to tilt and does not satisfactorily distinguish POTS from control in patients aged < 19 years old.