错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Asystole on loop recorder in patients with unexplained syncope and negative tilt testing: age distribution and clinical predictors

  • Vincenzo Russo,
  • Angelo Comune,
  • Erika Parente,
  • Anna Rago,
  • Andrea Antonio Papa,
  • Gerardo Nigro,
  • Michele Brignole

摘要

Background

Approximately 50% of patients with unexplained syncope and negative head-up tilt test (HUTT) who have an electrocardiogram (ECG) documentation of spontaneous syncope during implantable loop recorder (ILR) show an asystolic pause at the time of the event.

Objective

The aim of the study was to evaluate the age distribution and clinical predictors of asystolic syncope detected by ILR in patients with unexplained syncope and negative HUTT.

Methods

This research employed a retrospective, single-center study of consecutive patients. The ILR-documented spontaneous syncope was classified according to the International Study on Syncope of Uncertain Etiology (ISSUE) classification.

Results

Among 113 patients (54.0 ± 19.6 years; 46% male), 49 had an ECG-documented recurrence of syncope during the observation period and 28 of these later (24.8%, corresponding to 57.1% of the patients with a diagnostic event) had a diagnosis of asystolic syncope at ILR: type 1A was present in 24 (85.7%), type 1B in 1 (3.6%), and type 1C in 3 (10.7%) patients. The age distribution of asystolic syncope was bimodal, with a peak at age < 19 years and a second peak at the age of 60–79 years. At Cox multivariable analysis, syncope without prodromes (OR 3.7; p = 0.0008) and use of beta blockers (OR 3.2; p = 0.002) were independently associated to ILR-detected asystole.

Conclusions

In patients with unexplained syncope and negative HUTT, the age distribution of asystolic syncope detected by ILR is bimodal, suggesting a different mechanism responsible for asystole in both younger and older patients. The absence of prodromes and the use of beta blockers are independent predictors of ILR-detected asystole.