Background <p>The triple rule-out computed tomography angiography (TRO-CTA) has recently emerged as a technique that noninvasively evaluates the coronary arteries (CAs), the pulmonary arteries (PAs) and the thoracic aorta (TA).</p> Objective <p>To evaluate the feasibility of an optimized scanning protocol to reduce the volume of iodine contrast media (ICM), injection rate, and radiation dose in patients undergoing TRO-CTA.</p> Methods <p>Patients undergoing TRO-CTA were assigned to either group A or group B using a 16&#xa0;cm wide-detector CT. Patients in group A were imaged with a traditional triple scanning protocol with a sequence of the PA, CAs, and TA. Patients in group B were imaged using the modified protocol with scanning sequence of PA, TA, and CAs, ICM of 55&#xa0;ml, and injection rate of 4.5 mL/s. The image quality and effective radiation dose (ED) were compared.</p> Results <p>There were no significant differences in basic information between groups A and B. Other than the left PA, RA, and RV, there were no significant differences in the CT attenuation values of relevant vascular structures between groups A and B. There were no significant differences in CNR values between the two groups except the LAD-D and LCX. The image quality scores were comparable between groups A and B except the CAs. However, there were significant differences between the two groups in ICM (<i>p</i> &lt; 0.05), scanning time (<i>p</i> &lt; 0.001) and ED (<i>p</i> = 0. 023).</p> Conclusions <p>The optimized TRO-CTA scanning protocol can achieve less ICM and lower ED while maintaining image quality.</p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Wide-Detector CT-Based optimized triple Rule-Out CT angiography for emergency chest pain: reducing contrast and radiation without compromising diagnostic quality

  • Qiuhua Zhang,
  • Kun Wang,
  • Hong Ren

摘要

Background

The triple rule-out computed tomography angiography (TRO-CTA) has recently emerged as a technique that noninvasively evaluates the coronary arteries (CAs), the pulmonary arteries (PAs) and the thoracic aorta (TA).

Objective

To evaluate the feasibility of an optimized scanning protocol to reduce the volume of iodine contrast media (ICM), injection rate, and radiation dose in patients undergoing TRO-CTA.

Methods

Patients undergoing TRO-CTA were assigned to either group A or group B using a 16 cm wide-detector CT. Patients in group A were imaged with a traditional triple scanning protocol with a sequence of the PA, CAs, and TA. Patients in group B were imaged using the modified protocol with scanning sequence of PA, TA, and CAs, ICM of 55 ml, and injection rate of 4.5 mL/s. The image quality and effective radiation dose (ED) were compared.

Results

There were no significant differences in basic information between groups A and B. Other than the left PA, RA, and RV, there were no significant differences in the CT attenuation values of relevant vascular structures between groups A and B. There were no significant differences in CNR values between the two groups except the LAD-D and LCX. The image quality scores were comparable between groups A and B except the CAs. However, there were significant differences between the two groups in ICM (p < 0.05), scanning time (p < 0.001) and ED (p = 0. 023).

Conclusions

The optimized TRO-CTA scanning protocol can achieve less ICM and lower ED while maintaining image quality.