错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

An ASER AI/ML expert panel formative user research study for an interpretable interactive splenic AAST grading graphical user interface prototype

  • Nathan Sarkar,
  • Mitsuo Kumagai,
  • Samantha Meyr,
  • Sriya Pothapragada,
  • Mathias Unberath,
  • Guang Li,
  • Sagheer Rauf Ahmed,
  • Elana Beth Smith,
  • Melissa Ann Davis,
  • Garvit Devmohan Khatri,
  • Anjali Agrawal,
  • Zachary Scott Delproposto,
  • Haomin Chen,
  • Catalina Gómez Caballero,
  • David Dreizin

摘要

Purpose

The AAST Organ Injury Scale is widely adopted for splenic injury severity but suffers from only moderate inter-rater agreement. This work assesses SpleenPro, a prototype interactive explainable artificial intelligence/machine learning (AI/ML) diagnostic aid to support AAST grading, for effects on radiologist dwell time, agreement, clinical utility, and user acceptance.

Methods

Two trauma radiology ad hoc expert panelists independently performed timed AAST grading on 76 admission CT studies with blunt splenic injury, first without AI/ML assistance, and after a 2-month washout period and randomization, with AI/ML assistance. To evaluate user acceptance, three versions of the SpleenPro user interface with increasing explainability were presented to four independent expert panelists with four example cases each. A structured interview consisting of Likert scales and free responses was conducted, with specific questions regarding dimensions of diagnostic utility (DU); mental support (MS); effort, workload, and frustration (EWF); trust and reliability (TR); and likelihood of future use (LFU).

Results

SpleenPro significantly decreased interpretation times for both raters. Weighted Cohen’s kappa increased from 0.53 to 0.70 with AI/ML assistance. During user acceptance interviews, increasing explainability was associated with improvement in Likert scores for MS, EWF, TR, and LFU. Expert panelists indicated the need for a combined early notification and grading functionality, PACS integration, and report autopopulation to improve DU.

Conclusions

SpleenPro was useful for improving objectivity of AAST grading and increasing mental support. Formative user research identified generalizable concepts including the need for a combined detection and grading pipeline and integration with the clinical workflow.