Objectives <p>Invasive pulmonary aspergillosis (IPA) is a potentially fatal complication in patients with connective tissue disease-associated interstitial lung disease (CTD-ILD). The aim of this study is to investigate the clinical significance of CD3 + CD4 + T cells counts in CTD-ILD with IPA patients.</p> Methods <p>This retrospective study included 152 CTD-ILD patients admitted to a single center in China between January 2018 and June 2020. A total of 54 CTD-ILD patients with IPA were assigned to the CTD-ILD with IPA group, while 98 uninfected CTD-ILD patients were assigned to the control group. Serum CD3 + CD4 + T cells counts were compared between the above-mentioned two groups, and the correlations between CD3 + CD4 + T cells counts and the clinical features, mortality of CTD-ILD with IPA were also evaluated.</p> Results <p>CTD-ILD patients with IPA had significantly lower CD3 + CD4 + T cells counts than those with CTD-ILD without IPA (<i>P</i> &lt; 0.001). The area under the receiver operating characteristic curve (AUROC) of discriminating CTD-ILD with IPA from CTD-ILD without IPA was 0.800 (95% CI, 0.722–0.878, <i>P</i> &lt; 0.001). Correlation analyses showed that serum CD3 + CD4 + T cells counts were positively correlated with PaO2/FiO2 ratio(<i>r</i> = 0.317, <i>P</i> = 0.034) and negatively correlated with C reactive protein (CRP) (<i>r</i> = − 0.358, <i>P</i> = 0.009), erythrocyte sedimentation rate (ESR) (<i>r</i> = − 0.346, <i>P</i> = 0.014), and lactate dehydrogenase (LDH) (<i>r</i> = − 0.306, <i>P</i> = 0.026). In addition, 30 decedents with CTD-ILD infected IPA exhibited lower values of CD3 + CD4 + T cells compared with 24 survivors (<i>P</i> = 0.041). Furthermore, CD3 + CD4 + T cells counts were a prognostic factor and also associated with a higher mortality rate (log-rank test, <i>P</i> = 0.003).</p> Conclusion <p>CD3 + CD4 + T cells counts could be a useful serum indicator associated with occurrence of IPA in CTD-ILD. Moreover, decreased CD3 + CD4 + T cells counts were associated with a poor survival of IPA in CTD-ILD patients.<Table Float="No" ID="Taba"> <tgroup cols="2"> <colspec align="left" colname="c1" colnum="1" /> <colspec align="left" colname="c2" colnum="2" /> <tbody> <row> <entry align="left" nameend="c2" namest="c1"> <p><b>Key Points</b></p> <p><i>• CTD-ILD patients with IPA had significantly lower CD3+CD4+T cells counts than those with CTD-ILD without IPA.</i></p> <p><i>• Correlation analyses showed that serum CD3+CD4+T cells counts were positively correlated with PaO2/FiO2 ratio and negatively correlated with C reactive protein (CRP), erythrocyte sedimentation rate (ESR) and lactate dehydrogenase (LDH).</i></p> <p><i>• Decreased CD3+CD4+T cells counts were associated with a poor survival of IPA in CTD-ILD patients.</i></p> </entry> </row> </tbody> </tgroup> </Table></p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

CD3 + CD4 + T cells counts reflect the severity and prognosis of invasive pulmonary aspergillosis in patients with connective tissue disease-associated interstitial lung disease

  • Shenyun Shi,
  • Ruyi Zou,
  • Rui Li,
  • Tingting Zhao,
  • Chao Wu,
  • Yonglong Xiao,
  • Xuebing Feng,
  • Lulu Chen

摘要

Objectives

Invasive pulmonary aspergillosis (IPA) is a potentially fatal complication in patients with connective tissue disease-associated interstitial lung disease (CTD-ILD). The aim of this study is to investigate the clinical significance of CD3 + CD4 + T cells counts in CTD-ILD with IPA patients.

Methods

This retrospective study included 152 CTD-ILD patients admitted to a single center in China between January 2018 and June 2020. A total of 54 CTD-ILD patients with IPA were assigned to the CTD-ILD with IPA group, while 98 uninfected CTD-ILD patients were assigned to the control group. Serum CD3 + CD4 + T cells counts were compared between the above-mentioned two groups, and the correlations between CD3 + CD4 + T cells counts and the clinical features, mortality of CTD-ILD with IPA were also evaluated.

Results

CTD-ILD patients with IPA had significantly lower CD3 + CD4 + T cells counts than those with CTD-ILD without IPA (P < 0.001). The area under the receiver operating characteristic curve (AUROC) of discriminating CTD-ILD with IPA from CTD-ILD without IPA was 0.800 (95% CI, 0.722–0.878, P < 0.001). Correlation analyses showed that serum CD3 + CD4 + T cells counts were positively correlated with PaO2/FiO2 ratio(r = 0.317, P = 0.034) and negatively correlated with C reactive protein (CRP) (r = − 0.358, P = 0.009), erythrocyte sedimentation rate (ESR) (r = − 0.346, P = 0.014), and lactate dehydrogenase (LDH) (r = − 0.306, P = 0.026). In addition, 30 decedents with CTD-ILD infected IPA exhibited lower values of CD3 + CD4 + T cells compared with 24 survivors (P = 0.041). Furthermore, CD3 + CD4 + T cells counts were a prognostic factor and also associated with a higher mortality rate (log-rank test, P = 0.003).

Conclusion

CD3 + CD4 + T cells counts could be a useful serum indicator associated with occurrence of IPA in CTD-ILD. Moreover, decreased CD3 + CD4 + T cells counts were associated with a poor survival of IPA in CTD-ILD patients.

Key Points

• CTD-ILD patients with IPA had significantly lower CD3+CD4+T cells counts than those with CTD-ILD without IPA.

• Correlation analyses showed that serum CD3+CD4+T cells counts were positively correlated with PaO2/FiO2 ratio and negatively correlated with C reactive protein (CRP), erythrocyte sedimentation rate (ESR) and lactate dehydrogenase (LDH).

• Decreased CD3+CD4+T cells counts were associated with a poor survival of IPA in CTD-ILD patients.