Objectives <p>This in vitro study aimed to evaluate the effect of different application protocols of surface pre-reacted glass-ionomer (S-PRG) sealant on penetration ability, retention, and occlusal caries inhibition, in comparison with resin-based sealant (RBS) under simulated oral conditions.</p> Materials and methods <p>Eighty-four extracted human third molars were randomly assigned to five groups: S-PRG sealant applied per manufacturer’s instructions (G1), S-PRG with 37% phosphoric acid etching pretreatment (G2), S-PRG with fluoride varnish pretreatment (G3), RBS (G4), and a no-sealant control (G5). Sealant retention was assessed through visual inspection following water storage at 37&#xa0;°C and thermocycling, whereas penetration depth was evaluated using scanning electron microscopy (SEM). Caries inhibition was evaluated via mineral density changes (ΔMDV) measured by micro-CT after 21-day pH cycling and <i>Streptococcus mutans</i> bacterial challenge. Statistical analysis included Kruskal-Wallis tests, Mann-Whitney U tests with Bonferroni correction, Chi-square tests, Spearman’s correlation, and multiple linear regression analyses.</p> Results <p>No statistically significant differences in sealant retention were found among the groups. RBS (G4) exhibited the highest median penetration (100%), followed by G2 (85.0%), G1 (59.5%), and G3 (44.5%), with significant differences among specific pairwise comparisons (<i>p</i> &lt; 0.001). No significant difference in ΔMDV were observed in pH cycling, but bacterial testing revealed significantly lower ΔMDV in G2 and G4 compared to G3 and G5 (<i>p</i> ≤ 0.005).</p> Conclusions <p>S-PRG sealants pretreated with phosphoric acid etching demonstrated significantly greater caries inhibition effects compared to using self-etched primer alone, and its caries prevention efficacies were comparable to that of RBS.</p> Clinical relevance <p>These in vitro findings support the use of phosphoric acid etching to enhance the performance of S-PRG sealants.</p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Efficacy of sealants with surface pre-reacted glass (S-PRG) in retention, fissure penetration and occlusal caries Inhibition

  • Steve H.C. Yeh,
  • Mohamed M.A. Abdalla,
  • Phoebe P.Y. Lam,
  • Cynthia K.Y. Yiu

摘要

Objectives

This in vitro study aimed to evaluate the effect of different application protocols of surface pre-reacted glass-ionomer (S-PRG) sealant on penetration ability, retention, and occlusal caries inhibition, in comparison with resin-based sealant (RBS) under simulated oral conditions.

Materials and methods

Eighty-four extracted human third molars were randomly assigned to five groups: S-PRG sealant applied per manufacturer’s instructions (G1), S-PRG with 37% phosphoric acid etching pretreatment (G2), S-PRG with fluoride varnish pretreatment (G3), RBS (G4), and a no-sealant control (G5). Sealant retention was assessed through visual inspection following water storage at 37 °C and thermocycling, whereas penetration depth was evaluated using scanning electron microscopy (SEM). Caries inhibition was evaluated via mineral density changes (ΔMDV) measured by micro-CT after 21-day pH cycling and Streptococcus mutans bacterial challenge. Statistical analysis included Kruskal-Wallis tests, Mann-Whitney U tests with Bonferroni correction, Chi-square tests, Spearman’s correlation, and multiple linear regression analyses.

Results

No statistically significant differences in sealant retention were found among the groups. RBS (G4) exhibited the highest median penetration (100%), followed by G2 (85.0%), G1 (59.5%), and G3 (44.5%), with significant differences among specific pairwise comparisons (p < 0.001). No significant difference in ΔMDV were observed in pH cycling, but bacterial testing revealed significantly lower ΔMDV in G2 and G4 compared to G3 and G5 (p ≤ 0.005).

Conclusions

S-PRG sealants pretreated with phosphoric acid etching demonstrated significantly greater caries inhibition effects compared to using self-etched primer alone, and its caries prevention efficacies were comparable to that of RBS.

Clinical relevance

These in vitro findings support the use of phosphoric acid etching to enhance the performance of S-PRG sealants.