Objectives <p>The aim of this study is to compare the biomechanical effects of maxillary first molar intrusion using the fixed appliance, microimplant, and clear aligner with or without 3D printed personalized device, and to demonstrate the effect of this device through a relevant clinical case.</p> Methods <p>A clinical patient with an overerupted maxillary molar was selected to construct a patient-oriented three-dimensional model of the four intrusion patterns. The initial displacement of the teeth and the stress distribution of the PDL were compared. The 3D printed personalized device was used in this case, and the data of the case was collected to assess the therapeutic effect.</p> Results <p>The side effects of target tooth tilt and adjacent tooth displacement were obvious in fixed appliance and clear aligner, while the side effects were smaller in 3D printed personalized device, and the intrusion efficiency is slightly higher than that of microimplant. In clinical practice of 3D printed personalized device, a favorable intrusion effect was achieved.</p> Conclusions <p>The 3D printed personalized device had relatively high intrusion efficiency and stress relaxation on the target tooth and reduced the displacement and stress concentration on the anchorage teeth to a certain extent.</p> Clinical relevance <p>In clinical practice, clear aligner with 3D printed personalized device has a good therapeutic effect on molar intrusion.</p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Biomechanical analysis of maxillary first molar intrusion using 3D printed personalized device combined with clear aligner: a finite element study and clinical application

  • Qin Xue,
  • Mei Hu,
  • Minglu Xu,
  • Xuyang Zhang,
  • Huaqiao Wang,
  • Mimi Sun,
  • Chunjuan Wang,
  • Yao He

摘要

Objectives

The aim of this study is to compare the biomechanical effects of maxillary first molar intrusion using the fixed appliance, microimplant, and clear aligner with or without 3D printed personalized device, and to demonstrate the effect of this device through a relevant clinical case.

Methods

A clinical patient with an overerupted maxillary molar was selected to construct a patient-oriented three-dimensional model of the four intrusion patterns. The initial displacement of the teeth and the stress distribution of the PDL were compared. The 3D printed personalized device was used in this case, and the data of the case was collected to assess the therapeutic effect.

Results

The side effects of target tooth tilt and adjacent tooth displacement were obvious in fixed appliance and clear aligner, while the side effects were smaller in 3D printed personalized device, and the intrusion efficiency is slightly higher than that of microimplant. In clinical practice of 3D printed personalized device, a favorable intrusion effect was achieved.

Conclusions

The 3D printed personalized device had relatively high intrusion efficiency and stress relaxation on the target tooth and reduced the displacement and stress concentration on the anchorage teeth to a certain extent.

Clinical relevance

In clinical practice, clear aligner with 3D printed personalized device has a good therapeutic effect on molar intrusion.