错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Evaluation of stress and displacement of maxillary canine during the single canine retraction in the maxillary first premolar extraction cases- A finite element study

  • Wenbo Zhao,
  • Yu Lou,
  • Weijun Yan

摘要

Objectives

This finite element study aimed to simulate maxillary canine movement during anterior teeth retraction.

Materials and methods

Three methods of maxillary canine movement including miniscrew sliding with high hooks (MSH), miniscrew sliding with low hooks (MSL), and the traditional sliding method (TS) without using miniscrews were simulated using three-dimensional finite element analysis. The initial displacement of the maxillary canine, the maximum principal stress of the periodontal ligament and the Von Mises stress were calculated.

Results

The distolingual tipping movements of the canine were shown in three movement modes. MSH showed a small tendency to lingual tipping movement and a extrusion movement while MSL had the largest lingual inclination. TS demonstrated a tendency toward distolingual torsion displacement. Compressive stress values were mainly concentrated in the range − 0.003 to -0.006 MPa. For tensile stress, the distribution of MSH and MSL was concentrated in the range 0.005 to 0.009 MPa, TS was mainly distributed about 0.003 MPa. Von Mises equivalent stress distribution showed no significant difference.

Conclusions

The loss of tooth torque was inevitable, irrespective of which method was used to close the extraction space. However, miniscrew application and higher hooks reduced the loss of torque and avoided lingual rotation.

Clinical relevance

This study shows that miniscrew implants with different hooks can better control the movement of the maxillary canines. The non-invasive nature of the finite element analysis and its good simulation of dental stress and instantaneous motion trend have a clinical advantage in the analysis of tooth movement.