<p>A molecularly imprinted electrochemical sensor (MIP) was developed using thymine-functionalized carbon nanofibers (Thy@CNFs) to enable selective detection of hypoxanthine (HYP). The sensor was fabricated by first depositing Thy@CNFs onto a glassy carbon electrode (GCE), followed by electropolymerization of a pyrrole-co-pyrrole-3-carboxylic acid (Py-co-PyCOOH) copolymer in the presence of HYP. Each modification step was characterized using electrochemical impedance spectroscopy (EIS), cyclic voltammetry (CV), attenuated total reflection-Fourier transform infrared spectroscopy (ATR-FTIR), scanning electron microscopy (SEM), and contact angle measurements. Under optimized conditions, the Thy@CNFs-modified MIP sensor (Thy@CNFs/MIP/GCE) exhibited a linear response to HYP concentrations ranging from 1 × 10<sup>−9</sup> to 1 × 10<sup>−8</sup>&#xa0;M, with a detection limit of 1.71 × 10<sup>−10</sup>&#xa0;M. Finally, the sensor was successfully applied to commercial serum and artificial urine sample, achieving recoveries of 99.55% and 100.17%, respectively, demonstrating its accuracy, precision, and practical applicability in real sample analysis.</p> Graphical Abstract <p></p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Carbon nanofiber–enhanced molecular imprinted electrochemical sensor for hypoxanthine detection

  • Canan Armutcu,
  • Sena Pişkin,
  • Erdoğan Özgür,
  • Mustafa Karakaya,
  • M. Emin Çorman,
  • Lokman Uzun

摘要

A molecularly imprinted electrochemical sensor (MIP) was developed using thymine-functionalized carbon nanofibers (Thy@CNFs) to enable selective detection of hypoxanthine (HYP). The sensor was fabricated by first depositing Thy@CNFs onto a glassy carbon electrode (GCE), followed by electropolymerization of a pyrrole-co-pyrrole-3-carboxylic acid (Py-co-PyCOOH) copolymer in the presence of HYP. Each modification step was characterized using electrochemical impedance spectroscopy (EIS), cyclic voltammetry (CV), attenuated total reflection-Fourier transform infrared spectroscopy (ATR-FTIR), scanning electron microscopy (SEM), and contact angle measurements. Under optimized conditions, the Thy@CNFs-modified MIP sensor (Thy@CNFs/MIP/GCE) exhibited a linear response to HYP concentrations ranging from 1 × 10−9 to 1 × 10−8 M, with a detection limit of 1.71 × 10−10 M. Finally, the sensor was successfully applied to commercial serum and artificial urine sample, achieving recoveries of 99.55% and 100.17%, respectively, demonstrating its accuracy, precision, and practical applicability in real sample analysis.

Graphical Abstract