<p> A&#xa0;fluorescent/colorimetric dual-mode biosensor was designed&#xa0;using CdTe QDs and CRISPR/Cas for the efficient and ultrasensitive detection of microcystin-leucine-arginine (MC-LR). The biosensor mainly activates the trans-cleavage activity of Cas12a through nucleic acid amplification technology, such as bidirectional rolling circle amplification (B-RCA), to perform signal conversion, release Ag<sup>+</sup> from the cleaving hairpin, quench QD fluorescence, and perform signal presentation. The biosensor can perform fluorometric and colorimetric detection, enabling rapid field assays. It exhibits enhanced selectivity, increased&#xa0;sensitivity, and greater accuracy. The optimal conditions yield a detection range from 0.05 to 500&#xa0;nM, with a minimum detectable concentration of 2.137&#xa0;pM, surpassing the performance of traditional methods. The biosensor can effectively detect MC-LR in actual environmental samples. Overall, this study provided a general detection approach for the application of nucleic acid detection technology to detect trace pollutants in the environment.</p> Graphical Abstract <p></p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Fluorescent/colorimetric dual-mode for detecting of MC-LR using bidirectional RCA coupled with CdTe QDs

  • Weiqing Sun,
  • Xinru Ren,
  • Yijing Xiao,
  • Bowen Li,
  • Qing-ao Pang,
  • Meili Yang,
  • Rui Zhu,
  • Zhiqiang Guo,
  • Jinghua Yu,
  • Jiadong Huang,
  • Yu Wang,
  • Su Liu

摘要

A fluorescent/colorimetric dual-mode biosensor was designed using CdTe QDs and CRISPR/Cas for the efficient and ultrasensitive detection of microcystin-leucine-arginine (MC-LR). The biosensor mainly activates the trans-cleavage activity of Cas12a through nucleic acid amplification technology, such as bidirectional rolling circle amplification (B-RCA), to perform signal conversion, release Ag+ from the cleaving hairpin, quench QD fluorescence, and perform signal presentation. The biosensor can perform fluorometric and colorimetric detection, enabling rapid field assays. It exhibits enhanced selectivity, increased sensitivity, and greater accuracy. The optimal conditions yield a detection range from 0.05 to 500 nM, with a minimum detectable concentration of 2.137 pM, surpassing the performance of traditional methods. The biosensor can effectively detect MC-LR in actual environmental samples. Overall, this study provided a general detection approach for the application of nucleic acid detection technology to detect trace pollutants in the environment.

Graphical Abstract