错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Multi-center study of use of the Exeter stem in Japan: a 10-year follow-up report

  • Tatsuro Sakurai,
  • Hiroshi Fujita,
  • Toshiki Iwase,
  • Kan Sasaki,
  • Naoyuki Katayama,
  • Hiromi Otsuka

摘要

Purpose

Since the introduction of the Exeter stem for clinical use in Japan in 1996, the number of stems used has continued to rise owing to its favorable results. We investigated the outcomes of patients who had previously undergone total hip arthroplasty with the Exeter stem in Japan with a 10-year + follow-up period.

Methods

This retrospective cohort study used clinical and radiographic data of 682 cases of primary total hip arthroplasty performed using the Exeter stem.

Results

The mean postoperative follow-up period was 13.3 years. Femoral-side revision was required in 14 hips, with no cases of aseptic stem loosening-associated revision observed. Kaplan–Meier survival analysis predicted 97.3% 15-year survival when revision for any reason was used as the endpoint.

Conclusion

The obtained findings suggested the excellent long-term stability of the Exeter stem for primary total hip arthroplasty in Japan.