错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Clinical and biological effects of different energetic surgical devices currently used for mini-invasive anatomical lung resections for the treatment of NSCLC: a prospective interventional study

  • Chiara Catelli,
  • Miriana D’Alessandro,
  • Federico Mathieu,
  • Emanuele Addamo,
  • Federico Franchi,
  • Piero Paladini,
  • Luca Luzzi

摘要

Background

This study aims to compare three commonly used energy devices for dissection during Video-Assisted Thoracoscopic Surgery (VATS) lobectomy: monopolar hook, advanced bipolar, and ultrasonic device, in terms of duration of the surgical procedure and clinical intra- and post-operative outcomes.

Materials and methods

In this prospective single-center study, 75 patients undergoing VATS lobectomy for non-small cell lung cancer between January 2022 and May 2023 were enrolled and divided into 3 groups based on the device used during the surgical procedure (Group 1: Ultrasonic Device, Group 2: Advanced Bipolar, Group 3: Monopolar Hook). The duration of the surgical procedure, daily pleural fluid production, post-operative pain, length of hospital stay, and occurrence of post-operative complications were compared for each group. In a subgroup of 20 patients (10 from Group 1 and 10 from Group 3), concentrations of inflammatory cytokines in pleural fluid at 3 h and 48 h post-surgery were analyzed.

Results

Pleural fluid production on the first and second post-operative days was significantly lower in patients treated with the Ultrasonic device compared to the other two groups (p < 0.001). The duration of the surgical procedure was significantly shorter when using the Ultrasonic device (p < 0.001). There were no significant differences in length of hospital stay (p = 0.975), pain on the first and second post-operative days (p = 0.147 and p = 0.755, respectively), and blood hemoglobin levels on the first post-operative day (p = 0.709) and at discharge (p = 0.795). No differences were observed in terms of post-operative complications, although the incidence of post-operative cardiac arrhythmias was borderline significant (p = 0.096), with no cases of arrhythmias recorded in Group 1. IL-10 levels in pleural fluid of patients in Group 3 peaked at 3 h post-surgery, with a significant reduction at 48 h (p = 0.459).

Discussion

The use of the ultrasonic device during VATS lobectomy may reduce pleural fluid production and shorten the duration of the surgical procedure compared to using a monopolar hook or advanced bipolar device. The choice of energy device may influence the local inflammatory response, although further studies are needed to confirm these results.