错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Novel gastric endoscopic submucosal dissection training model enhances the endoscopic submucosal dissection skills of trainees: a multicenter comparative study

  • Tomohiro Mitsui,
  • Hironori Sunakawa,
  • Yusuke Yoda,
  • Masafumi Nishio,
  • Shinpei Kondo,
  • Jun Hamanaka,
  • Chikako Tokoro,
  • Keiichiro Nakajo,
  • Shin Maeda,
  • Tomonori Yano,
  • Kingo Hirasawa

摘要

Background

Endoscopic submucosal dissection (ESD) requires high endoscopic technical skills, and trainees should develop effective training methods. In collaboration with KOTOBUKI Medical, we developed the G-Master, which is a non-animal training model that can simulate various parts of gastric ESD. We aimed to clarify the usefulness of the G-Master for inexperienced ESD trainees.

Methods

We collected data from the first 5 gastric ESD cases conducted by 15 inexperienced ESD trainees at 5 participating centers between 2018 and 2022. The participants were divided into two groups: the G-Master training and non-G-Master training groups. Outcome measurements, such as procedural speed, perforation rate, self-completion rate, and en bloc resection rate, were compared between the two groups retrospectively.

Results

A total of 75 gastric ESD cases were included in this study. The G-Master training group included 25 cases performed by 5 trainees, whereas the non-G-Master training group included 50 cases performed by 10 trainees. The median procedural speed for all cases was significantly faster in the G-Master training group than in the non-G-Master training group. Moreover, the procedural speed was linearly improved from the initial to the last cases in the lower location in the G-Master training group compared with the non-G-Master training group. In addition, although there was no significant difference, the G-Master training group showed lower rates of perforation and a lesser need to transition to expert operators than the non-G-Master training group.

Conclusion

The G-Master could improve the ESD skills of inexperienced ESD trainees.