<p>In this study, the JFX reflected shock tunnel freestream is characterized using pitot probes, laser absorption spectroscopy, and high-speed schlieren for shock stand-off distances over a sphere. The experiment employed two driver gases: a mixture of H<sub>2</sub> and CO<sub>2</sub>, and pure He. Three lasers, operating at wavelengths around 2.0 <InlineEquation ID="IEq1"> <InlineMediaObject> <ImageObject Color="BlackWhite" FileRef="348_2025_3967_Article_IEq1.gif" Format="GIF" Height="13" Rendition="HTML" Resolution="72" Type="Linedraw" Width="26" /> </InlineMediaObject> <EquationSource Format="TEX">\(\upmu \mathrm{m}\)</EquationSource> <EquationSource Format="MATHML"><math> <mrow> <mi mathvariant="normal">μ</mi> <mi mathvariant="normal">m</mi> </mrow> </math></EquationSource> </InlineEquation> and 1.4 <InlineEquation ID="IEq2"> <InlineMediaObject> <ImageObject Color="BlackWhite" FileRef="348_2025_3967_Article_IEq2.gif" Format="GIF" Height="13" Rendition="HTML" Resolution="72" Type="Linedraw" Width="26" /> </InlineMediaObject> <EquationSource Format="TEX">\(\upmu \mathrm{m}\)</EquationSource> <EquationSource Format="MATHML"><math> <mrow> <mi mathvariant="normal">μ</mi> <mi mathvariant="normal">m</mi> </mrow> </math></EquationSource> </InlineEquation> with a scanning frequency of 50&#xa0;kHz, were utilized to measure the properties of CO<sub>2</sub> and H<sub>2</sub>O. Computational fluid dynamics simulations showed near thermo-equilibrium conditions, supporting the use of an equilibrium model to determine the temperature and partial pressure of the two species. Isentropic calculations indicate that there is no significant thermodynamic nonequilibrium in the freestream. During the effective test time, the measured and simulated results were in good agreement for both the shock stand-off distance and CO<sub>2</sub> partial pressure. However, the detection of H<sub>2</sub>O indicated contamination from the driver gas, with early onset leading to an increase in the shock stand-off distance. The uncontaminated time is around 700-800 <InlineEquation ID="IEq3"> <InlineMediaObject> <ImageObject Color="BlackWhite" FileRef="348_2025_3967_Article_IEq3.gif" Format="GIF" Height="13" Rendition="HTML" Resolution="72" Type="Linedraw" Width="19" /> </InlineMediaObject> <EquationSource Format="TEX">\(\upmu \mathrm{s}\)</EquationSource> <EquationSource Format="MATHML"><math> <mrow> <mi mathvariant="normal">μ</mi> <mi mathvariant="normal">s</mi> </mrow> </math></EquationSource> </InlineEquation> for both conditions, and the contamination onset time falls between the predicted values using different nozzle conditions, which also indicates a certain degree of contamination.</p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Characterization of reflected shock tunnel freestream in carbon dioxide

  • Zhuo Liu,
  • Renjie Li,
  • Qiu Wang,
  • Fei Li,
  • Sangdi Gu

摘要

In this study, the JFX reflected shock tunnel freestream is characterized using pitot probes, laser absorption spectroscopy, and high-speed schlieren for shock stand-off distances over a sphere. The experiment employed two driver gases: a mixture of H2 and CO2, and pure He. Three lasers, operating at wavelengths around 2.0 \(\upmu \mathrm{m}\) μ m and 1.4 \(\upmu \mathrm{m}\) μ m with a scanning frequency of 50 kHz, were utilized to measure the properties of CO2 and H2O. Computational fluid dynamics simulations showed near thermo-equilibrium conditions, supporting the use of an equilibrium model to determine the temperature and partial pressure of the two species. Isentropic calculations indicate that there is no significant thermodynamic nonequilibrium in the freestream. During the effective test time, the measured and simulated results were in good agreement for both the shock stand-off distance and CO2 partial pressure. However, the detection of H2O indicated contamination from the driver gas, with early onset leading to an increase in the shock stand-off distance. The uncontaminated time is around 700-800 \(\upmu \mathrm{s}\) μ s for both conditions, and the contamination onset time falls between the predicted values using different nozzle conditions, which also indicates a certain degree of contamination.