Is the ablation stone efficacy and efficiency better with a flexible and navigable suction ureteric access sheath?
摘要
To compare the ablation efficacy and efficiency of flexible and navigable suction ureteric access sheath (FANS) and conventional ureteral access sheath (c-UAS) in retrograde intrarenal surgery (RIRS) for kidney stones treatment.
Materials and methodsA retrospective study of 96 patients who underwent RIRS using thulium fiber laser was performed. We divided the patients into Group 1: FANS and Group 2: c-UAS. We assessed the lithotripsy efficiency (mm3/Joules), ablation efficacy (mm3/min), and laser energy consumption (Joules/mm3). The stone-free rate (SFR) was defined as the absence of stone fragments in a non-contrast abdominal computed tomography 4-weeks after the procedure.
ResultsBoth groups presented comparable stone volume (mm3) and stone density. RIRS with FANS presented a significantly lower surgical time and laser energy consumption (10.9 vs. 12.1 Joules/mm3, p < 0.001). In addition, FANS presented higher ablation efficiency (0.22 vs. 0.09 mm3/Joules, p < 0.001) and ablation efficacy (26.1 vs. 19.9 mm3/min, p < 0.001). SFR was significantly higher in the FANS group (93.7% vs. 75%, p < 0.001).
ConclusionCompared to c-UAS, RIRS with FANS was associated with decreased total operative time and laser energy consumption and presented a significantly higher ablation efficacy and efficiency. Additionally, SFR was significantly higher in the FANS group.