Deep learning-driven false-lumen volumes predict adverse remodeling better than diameter in patients with residual aortic dissection on CT
摘要
1. To develop a deep-learning segmentation model for automated measurement of maximal aortic diameter (Dmax) and volumes of aortic dissection components: true-lumen (TL), circulating false-lumen (CFL), and thrombus (Th) on CT angiography (CTA). 2. To assess the predictive value of these measures for adverse aortic remodeling in residual aortic dissection (RAD).
Materials and methodsThis retrospective study included 322 patients from two centers. The segmentation model was trained on 120 patients (Center 1) and tested on an internal dataset (30 patients, Center 1) and an external dataset (10 patients, Center 2) in terms of Dice Similarity Coefficient (DSC). The model extracted Dmax, global false-lumen volume (FLGlo = CFL + Th), and local false-lumen volume (FLLoc, measured 3 cm around the largest diameter). Clinical validation was performed on 83 patients from Center1 (internal validation, 2-year follow-up) and 79 patients from Center2 (external validation, 4.5-year follow-up).
ResultsThe segmentation model achieved high accuracy (Center 1, DSC: 0.93 TL, 0.93 CFL, 0.87 Th; Center 2, DSC: 0.92 TL, 0.93 CFL, 0.84 Th) with strong agreement between automated and manual measurements. Aortic remodeling occurred in 39/83 patients (46.9%) from Center1 and 33/79 patients (41.7%) from Center2. Aortic remodeling occurred in 39/83 patients (47%) from Center1 and 33/80 (42%) from Center2. FLLoc outperformed Dmax and FLGlo (Center 1: AUC = 0.83, 0.73, and 0.76; Center 2: AUC = 0.77, 0.64, and 0.70). At optimal thresholds, FLLoc showed good predictive performance (Center 1: Sensitivity = 0.87, Specificity = 0.68).
ConclusionDeep-learning segmentation provides accurate aortic measurements. Local false-lumen volumes predict adverse aortic remodeling in RAD better than diameter and global false-lumen volumes.
Key Points