Objectives <p>To evaluate GPT-4o’s zero-shot ability to extract structured diagnostic labels (with uncertainty) from free-text radiology reports and to test how these labels affect multi-label image classification of musculoskeletal radiographs.</p> Materials and methods <p>This retrospective study included radiography series of the clavicle (<i>n</i> = 1170), elbow (<i>n</i> = 3755), and thumb (<i>n</i> = 1978). After anonymization, GPT-4o filled out structured templates by indicating imaging findings as present (“true”), absent (“false”), or “uncertain.” To assess the impact of label uncertainty, “uncertain” labels of the training and validation sets were automatically reassigned to “true” (inclusive) or “false” (exclusive). Label-image pairs were used for multi-label classification using the ResNet50 architecture. Label extraction accuracy was manually verified on internal (clavicle: <i>n</i> = 233, elbow: <i>n</i> = 745, thumb: <i>n</i> = 393) and external test sets (<i>n</i> = 300 for each). Performance was assessed using macro-averaged receiver operating characteristic (ROC) area under the curve (AUC), precision, recall curves, sensitivity, specificity, and accuracy. AUCs were compared with the DeLong test.</p> Results <p>Automatic extraction was correct in 98.6% (60,618 of 61,488) of labels in the test sets. Across anatomic regions, label-based model training yielded competitive performance measured by macro-averaged AUC values for inclusive (e.g., elbow: AUC = 0.80 (range, 0.62–0.87)) and exclusive models (elbow: AUC = 0.80 (range, 0.61–0.88)). Models generalized well on external datasets (elbow (inclusive): AUC = 0.79 (range, 0.61–0.87); elbow (exclusive): AUC = 0.79 (range, 0.63–0.89)). No significant differences were observed across labeling strategies or datasets (<i>p </i>≥ 0.15).</p> Conclusion <p>GPT-4o extracted labels from radiologic reports to train competitive multi-label classification models with high accuracy. Detected uncertainty in the radiologic reports did not influence the performance of these models.</p> Key Points <p><Emphasis Type="BoldItalic">Question</Emphasis> <i>Can GPT-4o automatically extract high-accuracy, uncertainty-aware diagnostic labels from routine radiologic reports of the clavicle, elbow, and thumb for use in training multi-label image classifiers?</i></p> <p><Emphasis Type="BoldItalic">Findings</Emphasis> <i>GPT-4o extracted labels with &gt; 98% accuracy, and multi-label classifiers for clavicle, elbow, and thumb radiographs performed consistently regardless of how uncertainty was handled.</i></p> <p><Emphasis Type="BoldItalic">Clinical relevance</Emphasis> <i>Automated GPT-4o-based labeling of routine clavicle, elbow, and thumb radiologic reports enables the rapid conversion of radiologic reports into structured multi-label training datasets, supporting scalable development of dedicated image classification models.</i></p> Graphical Abstract <p></p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Large language model-based uncertainty-adjusted label extraction for artificial intelligence model development in upper extremity radiography

  • Hanna Kreutzer,
  • Anne-Sophie Caselitz,
  • Thomas Dratsch,
  • Daniel Pinto dos Santos,
  • Christiane Kuhl,
  • Daniel Truhn,
  • Sven Nebelung

摘要

Objectives

To evaluate GPT-4o’s zero-shot ability to extract structured diagnostic labels (with uncertainty) from free-text radiology reports and to test how these labels affect multi-label image classification of musculoskeletal radiographs.

Materials and methods

This retrospective study included radiography series of the clavicle (n = 1170), elbow (n = 3755), and thumb (n = 1978). After anonymization, GPT-4o filled out structured templates by indicating imaging findings as present (“true”), absent (“false”), or “uncertain.” To assess the impact of label uncertainty, “uncertain” labels of the training and validation sets were automatically reassigned to “true” (inclusive) or “false” (exclusive). Label-image pairs were used for multi-label classification using the ResNet50 architecture. Label extraction accuracy was manually verified on internal (clavicle: n = 233, elbow: n = 745, thumb: n = 393) and external test sets (n = 300 for each). Performance was assessed using macro-averaged receiver operating characteristic (ROC) area under the curve (AUC), precision, recall curves, sensitivity, specificity, and accuracy. AUCs were compared with the DeLong test.

Results

Automatic extraction was correct in 98.6% (60,618 of 61,488) of labels in the test sets. Across anatomic regions, label-based model training yielded competitive performance measured by macro-averaged AUC values for inclusive (e.g., elbow: AUC = 0.80 (range, 0.62–0.87)) and exclusive models (elbow: AUC = 0.80 (range, 0.61–0.88)). Models generalized well on external datasets (elbow (inclusive): AUC = 0.79 (range, 0.61–0.87); elbow (exclusive): AUC = 0.79 (range, 0.63–0.89)). No significant differences were observed across labeling strategies or datasets (p ≥ 0.15).

Conclusion

GPT-4o extracted labels from radiologic reports to train competitive multi-label classification models with high accuracy. Detected uncertainty in the radiologic reports did not influence the performance of these models.

Key Points

Question Can GPT-4o automatically extract high-accuracy, uncertainty-aware diagnostic labels from routine radiologic reports of the clavicle, elbow, and thumb for use in training multi-label image classifiers?

Findings GPT-4o extracted labels with > 98% accuracy, and multi-label classifiers for clavicle, elbow, and thumb radiographs performed consistently regardless of how uncertainty was handled.

Clinical relevance Automated GPT-4o-based labeling of routine clavicle, elbow, and thumb radiologic reports enables the rapid conversion of radiologic reports into structured multi-label training datasets, supporting scalable development of dedicated image classification models.

Graphical Abstract