Dynamic perfusion area-detector CT in non-small cell lung cancer with progressive fibrosing interstitial lung disease
摘要
To determine the capability of dynamic contrast-enhanced (CE-) perfusion area-detector CT (ADCT) for detecting pathological structural changes in stage I non-small cell lung cancer (NSCLC) patients.
Materials and methodsSixty-three consecutive stage I NSCLC patients with progressive fibrosing interstitial lung disease (PF-ILD) underwent dynamic CE-perfusion ADCT analyzed by dual-input maximum slope (DMS) methods for total, pulmonary arterial and systemic arterial perfusion (TPDMS, PAPDMS and SAPDMS) maps, surgical treatment and pathological examination. Multicentric ROIs were then placed over sites assessed as normal lung, pulmonary emphysema, GGO or reticular pattern without traction bronchiectasis, reticular pattern with traction bronchiectasis and honeycombing in the resected lung. Next, an analysis of variance (ANOVA) followed by Tukey’s honest significant difference (HSD) multiple comparison test was performed for a comparison of each of the perfusion parameters for five groups. Finally, discrimination accuracy for evaluation of lung parenchymal change was compared for all indexes and combined methods.
ResultsPAPDMSs of abnormal lungs were significantly lower than that of normal lungs (p < 0.0001). SAPDMSs of normal or emphysematous lungs were significantly lower than those of others (p < 0.0001). SAPDMS of GGO or reticular pattern without traction bronchiectasis was significantly lower than that for reticular pattern with traction bronchiectasis and honeycombing (p < 0.0001). Discrimination accuracy of combined perfusion index was significantly higher than that of each index (p < 0.0001).
ConclusionDynamic CE-perfusion ADCT is useful for detecting pathological structural changes in stage I NSCLC patients with PF-ILD.
Key Points