Use of diagnostic vs low-dose computed tomography in positron emission tomography-CT examinations
摘要
To examine CT radiation dose variation in PET-CT and understand how often providers use diagnostic vs lower doses for attenuation correction and anatomic localization (AC/AL).
MethodsRetrospective, multi-centered study of PET-CT exams from 2010 to 2021. Exams were categorized as body or brain. Radiation dose was quantified using dose length product (DLP), adjusted for patient size (DLPS-ADJ), and for size and scan length (DLPSL-ADJ). DLPS-ADJ variation was assessed by body region and facility. To ascertain whether sites use AC/AL or diagnostic doses, we compared each facility’s DLPS-ADJ in CTs from PET-CT vs diagnostic CT exams of analogous body regions (not associated with PET), controlling for scan length using DLPSL-ADJ. Lastly, we categorized exams as likely diagnostic if they used multiple phases and/or contrast to compare dose and frequency with likely non-diagnostic exams.
ResultsSixty-four thousand two hundred ten exams included 93% body, 7% brain. Doses were higher and more variable in the body than brain exams (adult mean DLPS-ADJ = 1004 vs 341 mGy-cm, respectively). For body exams, DLPS-ADJ was higher in older children than adults, and there was wide inter-facility variation (median DLPS-ADJ range = 245–2391 mGy-cm). Most facilities used higher CT doses in body PET-CT than in diagnostic CT exams even controlling for scan length. Fifty-three percent of adult and 76% of child body exams were likely diagnostic based on the use of diagnostic techniques.
ConclusionWhile diagnostic CT is sometimes indicated for PET-CT, body exams generally do not use AC/AL protocols. Doses were higher than previously reported, higher than analogous diagnostic CT exams, and higher in older children than adults when size adjusted.
Key Points