PI-QUAL version 2 image quality categorisation and inter-reader agreement compared to version 1
摘要
Prostate imaging quality (PI-QUAL) was developed to standardise the evaluation of prostate MRI quality and has recently been updated to version 2. This study aims to assess inter-reader agreement for PI-QUAL v1 and v2 scores and investigates changes in MRI quality score categories.
Materials and methodsThe study retrospectively analysed 350 multiparametric MRI (mpMRI) scans. Two expert uroradiologists independently assessed mpMRI quality using PI-QUAL v1 and v2 guidelines. Biparametric MRI (bpMRI) categorisation based on PI-QUAL v2 included only T2WI and diffusion-weighted imaging (DWI) results. Inter-reader agreement was determined using percentage agreement and kappa, and categorisation comparisons were made using the chi-square test.
ResultsSubstantial inter-reader agreement was observed for the overall PI-QUAL v1 score (κ = 0.64) and moderate agreement for v2 mpMRI (κ = 0.54) and v2 bpMRI scores (κ = 0.57). Inter-reader agreements on individual sequences were similar between v1 and v2 (kappa for individual sequences: T2WI, 0.46 and 0.49; DWI, 0.66 and 0.70; DCE, 0.71 and 0.61). Quality levels shifted from predominantly “optimal” in v1 (65%) down to “acceptable” using v2 (55%); p < 0.001. The addition of DCE increased the proportion of cases with at least “adequate” quality at mpMRI (64%) compared to bpMRI (30%); p < 0.001.
ConclusionThis study shows consistent inter-reader agreement between PI-QUAL v1 and v2, encompassing overall and individual sequence categorisation. A notable shift from “optimal” to “acceptable” quality was demonstrated when moving from v1 to v2, with DCE tending improving quality from “inadequate” (bpMRI) to “acceptable” (mpMRI).
Key Points