错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

PI-QUAL version 2 image quality categorisation and inter-reader agreement compared to version 1

  • Kang-Lung Lee,
  • Iztok Caglic,
  • Po-Hsiang Liao,
  • Dimitri A. Kessler,
  • Chao-Yu Guo,
  • Tristan Barrett

摘要

Objectives

Prostate imaging quality (PI-QUAL) was developed to standardise the evaluation of prostate MRI quality and has recently been updated to version 2. This study aims to assess inter-reader agreement for PI-QUAL v1 and v2 scores and investigates changes in MRI quality score categories.

Materials and methods

The study retrospectively analysed 350 multiparametric MRI (mpMRI) scans. Two expert uroradiologists independently assessed mpMRI quality using PI-QUAL v1 and v2 guidelines. Biparametric MRI (bpMRI) categorisation based on PI-QUAL v2 included only T2WI and diffusion-weighted imaging (DWI) results. Inter-reader agreement was determined using percentage agreement and kappa, and categorisation comparisons were made using the chi-square test.

Results

Substantial inter-reader agreement was observed for the overall PI-QUAL v1 score (κ = 0.64) and moderate agreement for v2 mpMRI (κ = 0.54) and v2 bpMRI scores (κ = 0.57). Inter-reader agreements on individual sequences were similar between v1 and v2 (kappa for individual sequences: T2WI, 0.46 and 0.49; DWI, 0.66 and 0.70; DCE, 0.71 and 0.61). Quality levels shifted from predominantly “optimal” in v1 (65%) down to “acceptable” using v2 (55%); p < 0.001. The addition of DCE increased the proportion of cases with at least “adequate” quality at mpMRI (64%) compared to bpMRI (30%); p < 0.001.

Conclusion

This study shows consistent inter-reader agreement between PI-QUAL v1 and v2, encompassing overall and individual sequence categorisation. A notable shift from “optimal” to “acceptable” quality was demonstrated when moving from v1 to v2, with DCE tending improving quality from “inadequate” (bpMRI) to “acceptable” (mpMRI).

Key Points

Question What are the agreement levels of image quality of prostate MRI by using PI-QUAL v1 and v2?

Findings Inter-reader agreement based on PI-QUAL v1 and v2 is comparable. Dynamic contrast enhancement (DCE) enables an overall shift from inadequate quality (at bpMRI) to acceptable quality (mpMRI).

Clinical relevance The inter-reader agreement on PI-QUAL v1 and v2 is equivalent. PI-QUAL v2 assesses prostate bpMRI as well as mpMRI quality. Transitioning from inadequate to acceptable between v2-bpMRI and v2-mpMRI highlights the role of DCE as an “image quality safety net.”