Intrauterine blood transfusion causes dose- and time-dependent signal alterations in the liver and the spleen on fetal magnetic resonance imaging
摘要
Intrauterine transfusions (IUTs) are a life-saving treatment for fetal anemia. However, with each transfusion, iron bypasses uptake regulation through the placenta and accumulates in fetal organs. Unlike other imaging modalities, fetal magnetic resonance imaging (MRI) is capable of non-invasively assessing fetal liver disease and/or organ iron overload. This study aimed to investigate the effects of IUTs on MRI findings in the fetal liver and spleen.
Study designFor this retrospective study, we included eight fetuses undergoing IUT and prenatal MRI from 2014 to 2023. The fetuses were gestational age-matched with a cohort that received fetal MRI for other indications, but no IUTs. Signal intensity (SI) and volumetric analyses of the liver and the spleen were performed.
ResultsFetuses receiving transfusions had significantly larger volumes of both liver (p = 0.003) and spleen (p = 0.029). T1 SI inversely correlated with the number of IUTs (Pearson’s r = −0.43, p = 0.099). This effect regressed over time (r = 0.69, p = 0.057). T2 SI did not correlate significantly with transfusion frequency but showed a strong positive correlation with the number of days between IUT and MRI (r = 0.91, p = 0.002). For splenic SI measures, similar effects were observed regarding T1 SI reduction per received transfusion (r = −0.36, p = 0.167) and recovery of T2 SI after IUT (r = 0.88, p = 0.004).
ConclusionThis is the first study to report the effects of IUTs on MRI data of fetal livers and spleens. We observed considerable dose- and time-dependent SI alterations of the liver and spleen following IUT. Furthermore, fetal hepatosplenomegaly can be expected following IUT.
Key Points