错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Dual-energy CT of acute bowel ischemia—influence on diagnostic accuracy and reader confidence

  • Moritz Oberparleiter,
  • Jan Vosshenrich,
  • Hanns-Christian Breit,
  • Philippe Kaiser,
  • Paul Hehenkamp,
  • Dorothee Harder,
  • Daniel T. Boll,
  • Christoph J. Zech,
  • Markus M. Obmann

摘要

Objectives

This study evaluates the advantages in diagnostic accuracy, confidence, and reading time of additional dual-energy CT-derived reconstructions for assessing acute bowel ischemia.

Methods and materials

This retrospective study includes 25 patients with surgically proven acute bowel ischemia and 25 gender- and age-matched controls who underwent biphasic abdominal dual-energy CT. Two fellowship-trained abdominal radiologists and two residents evaluated all cases with and without additional dual-energy CT-derived iodine maps and virtual non-contrast images. Diagnostic confidence was rated on a 10-point Likert scale. Reading time was recorded. The inter-reader agreement was assessed using Fleiss’ kappa. Sensitivity and specificity were compared using McNemar’s test, reader confidence, and reading times with the Wilcoxon signed-rank test.

Results

For conventional images alone, the inter-reader agreement was moderate (κ = 0.58), with a sensitivity of 77% (95% CI: 67.5–84.8%) and specificity of 90% (95% CI: 82.4–95.1%). Adding dual-energy CT images, inter-reader agreement increased to substantial (κ = 0.69), sensitivity increased significantly to 89% (95% CI: 81.2–94.4%, p = 0.02), while specificity increased non-significantly to 93% (95% CI: 86.1–97.1%, p = 0.51). Diagnostic confidence increased significantly from 8 (IQR: 6–8) to 9 (IQR: 8–9) (p < 0.01). Equivalent diagnostic accuracy and confidence increases were observed for fellowship-trained and resident radiologists. A non-significant increase in mean reading time per case from 196 s to 201 s was observed (p = 0.30).

Conclusion

Additional dual-energy CT reconstructions increase diagnostic accuracy and confidence without increasing reading time when evaluating suspected acute bowel ischemia. Both experienced and resident readers benefit from dual-energy CT images.

Key Points

Question There are too few clinical studies assessing the diagnostic accuracy of dual-energy CT (DECT) to recommend its use for evaluating suspected acute bowel ischemia.

Findings Adding DECT-derived iodine maps and virtual-non-contrast images increase reader sensitivity and confidence while maintaining high specificity when evaluating for acute mesenteric ischemia.

Clinical relevance Dual-energy CT should be used to investigate suspected acute bowel ischemia. Both diagnostic accuracy and confidence can be increased independent of reader experience without significantly increasing reading time.