Purpose <p>In shoulder arthroplasty, three-dimensional computed tomography (3D CT) has become the gold standard for preoperative version assessment. Meanwhile, postoperative version is usually evaluated using radiographs (XR), in particular an axillary view, in which the view of the scapular body is often truncated, preventing the scapular plane from being used as a reference. This study introduces the posterolateral acromion-to-coracoid (PLAC) line, which can be assessed on a standard truncated axillary radiograph.</p> Materials and methods <p>Forty-six shoulders were studied. Four angles were measured including 3D CT (CT Version), 3D CT PLAC line to glenoid face angle (CT PLAC-GFA), 2) radiographic PLAC line to glenoid face angle (XR PLAC-GFA), and 3) the radiographic glenoid vault line to glenoid face angle (XR GV-GFA). Variation and linear relationship between these angles were calculated.</p> Results <p>The mean difference between CT PLAC-GFA and XR PLAC-GFA was 1.0º (95% CI -0.7 to 2.8)(IQR = 8.5º, -3.0º to 5.4º), with a strong correlation on linear regression (R<sup>2</sup> = 0.76, p &lt; 0.001). XR PLAC-GFA and XR GV-GFA demonstrated strong correlations with CT measured version (R<sup>2</sup> = 0.72 and 0.70, respectively; <i>p</i> &lt; 0.001). Inter-rater reliability was excellent for all metrics (ICC ≥ 0.93).</p> Conclusions <p>The PLAC and the glenoid vault lines are highly reproducible references on truncated axillary views. These alternative reference lines allow accurate comparison of preoperative and postoperative glenoid orientation using standard axillary radiographs.</p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Assessing glenoid orientation on the axillary view: a novel technique using the posterolateral acromion-to-coracoid line

  • Michael Hachadorian,
  • Mihir Sheth,
  • Ermyas Kahsai,
  • Anastasia Whitson,
  • Corey Schiffman,
  • Frederick Matsen III,
  • Jason Hsu

摘要

Purpose

In shoulder arthroplasty, three-dimensional computed tomography (3D CT) has become the gold standard for preoperative version assessment. Meanwhile, postoperative version is usually evaluated using radiographs (XR), in particular an axillary view, in which the view of the scapular body is often truncated, preventing the scapular plane from being used as a reference. This study introduces the posterolateral acromion-to-coracoid (PLAC) line, which can be assessed on a standard truncated axillary radiograph.

Materials and methods

Forty-six shoulders were studied. Four angles were measured including 3D CT (CT Version), 3D CT PLAC line to glenoid face angle (CT PLAC-GFA), 2) radiographic PLAC line to glenoid face angle (XR PLAC-GFA), and 3) the radiographic glenoid vault line to glenoid face angle (XR GV-GFA). Variation and linear relationship between these angles were calculated.

Results

The mean difference between CT PLAC-GFA and XR PLAC-GFA was 1.0º (95% CI -0.7 to 2.8)(IQR = 8.5º, -3.0º to 5.4º), with a strong correlation on linear regression (R2 = 0.76, p < 0.001). XR PLAC-GFA and XR GV-GFA demonstrated strong correlations with CT measured version (R2 = 0.72 and 0.70, respectively; p < 0.001). Inter-rater reliability was excellent for all metrics (ICC ≥ 0.93).

Conclusions

The PLAC and the glenoid vault lines are highly reproducible references on truncated axillary views. These alternative reference lines allow accurate comparison of preoperative and postoperative glenoid orientation using standard axillary radiographs.