Purpose <p>Diagnosis of peritoneal invasion, lymph node metastasis, and hepatic metastasis is crucial in the decision-making process of ovarian tumor treatment. This study aimed to test the feasibility of low-dose abdominopelvic CT with an artificial intelligence iterative reconstruction (AIIR) for diagnosing peritoneal invasion, lymph node metastasis, and hepatic metastasis in pre-operative imaging of ovarian tumor.</p> Methods <p>This study prospectively enrolled 88 patients with pathology-confirmed ovarian tumors, where routine-dose CT at portal venous phase (120 kVp/ref. 200 mAs) with hybrid iterative reconstruction (HIR) was followed by a low-dose scan (120 kVp/ref. 40 mAs) with AIIR. The performance of diagnosing peritoneal invasion and lymph node metastasis was assessed using receiver operating characteristic (ROC) analysis with pathological results serving as the reference. The hepatic parenchymal metastases were diagnosed and signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were measured. The perihepatic structures were also scored on the clarity of porta hepatis, gallbladder fossa and intersegmental fissure.</p> Results <p>The effective dose of low-dose CT was 79.8% lower than that of routine-dose scan (2.64 ± 0.46 vs. 13.04 ± 2.25 mSv, <i>p</i> &lt; 0.001). The low-dose AIIR showed similar area under the ROC curve (AUC) with routine-dose HIR for diagnosing both peritoneal invasion (0.961 vs. 0.960, <i>p</i> = 0.734) and lymph node metastasis (0.711 vs. 0.715, <i>p</i> = 0.355). The 10 hepatic parenchymal metastases were all accurately diagnosed on the two image sets. The low-dose AIIR exhibited higher SNR and CNR for hepatic parenchymal metastases and superior clarity for perihepatic structures.</p> Conclusion <p>In low-dose pre-operative CT of ovarian tumor, AIIR delivers similar diagnostic accuracy for peritoneal invasion, lymph node metastasis, and hepatic metastasis, as compared to routine-dose abdominopelvic CT. It is feasible and diagnostically safe to apply up to 80% dose reduction in CT imaging of ovarian tumor by using AIIR.</p> Graphical abstract <p></p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

The utility of low-dose pre-operative CT of ovarian tumor with artificial intelligence iterative reconstruction for diagnosing peritoneal invasion, lymph node and hepatic metastasis

  • Xiaojia Cai,
  • Jintao Han,
  • Wanhui Zhou,
  • Fan Yang,
  • Jing Liu,
  • Qi Wang,
  • Ruxun Li

摘要

Purpose

Diagnosis of peritoneal invasion, lymph node metastasis, and hepatic metastasis is crucial in the decision-making process of ovarian tumor treatment. This study aimed to test the feasibility of low-dose abdominopelvic CT with an artificial intelligence iterative reconstruction (AIIR) for diagnosing peritoneal invasion, lymph node metastasis, and hepatic metastasis in pre-operative imaging of ovarian tumor.

Methods

This study prospectively enrolled 88 patients with pathology-confirmed ovarian tumors, where routine-dose CT at portal venous phase (120 kVp/ref. 200 mAs) with hybrid iterative reconstruction (HIR) was followed by a low-dose scan (120 kVp/ref. 40 mAs) with AIIR. The performance of diagnosing peritoneal invasion and lymph node metastasis was assessed using receiver operating characteristic (ROC) analysis with pathological results serving as the reference. The hepatic parenchymal metastases were diagnosed and signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were measured. The perihepatic structures were also scored on the clarity of porta hepatis, gallbladder fossa and intersegmental fissure.

Results

The effective dose of low-dose CT was 79.8% lower than that of routine-dose scan (2.64 ± 0.46 vs. 13.04 ± 2.25 mSv, p < 0.001). The low-dose AIIR showed similar area under the ROC curve (AUC) with routine-dose HIR for diagnosing both peritoneal invasion (0.961 vs. 0.960, p = 0.734) and lymph node metastasis (0.711 vs. 0.715, p = 0.355). The 10 hepatic parenchymal metastases were all accurately diagnosed on the two image sets. The low-dose AIIR exhibited higher SNR and CNR for hepatic parenchymal metastases and superior clarity for perihepatic structures.

Conclusion

In low-dose pre-operative CT of ovarian tumor, AIIR delivers similar diagnostic accuracy for peritoneal invasion, lymph node metastasis, and hepatic metastasis, as compared to routine-dose abdominopelvic CT. It is feasible and diagnostically safe to apply up to 80% dose reduction in CT imaging of ovarian tumor by using AIIR.

Graphical abstract