Doppler velocities in patent transjugular intrahepatic portosystemic shunts: an analysis of 10 mm vs. 8 mm shunts

  • Matthew Mitchell,
  • Kausthubh Hegde,
  • Avik Som,
  • Patrick Sutphin,
  • Sanjeeva Kalva

摘要

Purpose

To determine if ultrasound Doppler velocities within transjugular portosystemic shunts/direct intrahepatic portosystemic shunts (TIPS/DIPS) differ based on the stent diameter (8 mm vs. 10 mm) and report typical flow velocities at defined locations along the stent in patients with a patent TIPS/DIPS on venography.

Methods

This study retrospectively analyzed a cohort of TIPS/DIPS recipients at a large tertiary care hospital from 2017 to 2022. Sixty-nine patient-entries with patent TIPS/DIPS venograms and available intervening Doppler US were identified (8 mm n = 41; men: 70.7%, mean age: 57.5 years [range: 36–75 years]; 10-mm n = 28; men: 50%, mean age: 50.2 years [range: 24–74 years]).

Results

The mean Doppler velocities were significantly different at the mid-stent (184.7 cm/s in 8 mm stents and 148.9 cm/s in 10 mm stents; p = 0.03, 95% CI 4.1–67.5) and hepatic-venous-end of the TIPS/DIPS (172.4 cm/s in 8 mm stents and 141.3 cm/s in 10 mm stents; p = 0.02, 95% CI 5.2–57.0). The mean Doppler velocities were not significantly different at the portal vein end of the TIPS (140.7 cm/s in 8 mm stents and 146.8 cm/s in 10 mm stents; p = 0.77, 95% CI − 34.6–46.8) or in the main portal vein (46.8 cm/s in 8 mm stents and 53.0 cm/s in 10 mm stents; p = 0.29, 95% CI − 5.4–17.9). Peak velocities occurred at the mid-TIPS location for the majority of patent 8 mm TIPS (n = 22) and at the portal-end of TIPS for the majority of 10 mm TIPS (n = 12).

Conclusion

Normal Doppler velocities within TIPS/DIPS differ depending on the shunt diameter. These findings demonstrate a need for specific Doppler screening thresholds in assessing TIPS/DIPS stents of differing calibers.