Purpose <p>This study aims to investigate whether a diagnostic AI model can effectively support lesion detection and staging in non-small cell lung cancer (NSCLC) [<sup>1</sup>⁸F]FDG PET/CT studies, focusing on the distinction between technical segmentation accuracy and clinically meaningful performance.</p> Methods <p>In this retrospective single-centre study, [<sup>1</sup>⁸F]FDG PET/CT scans from 306 treatment-naïve NSCLC patients were reviewed with reference to multidisciplinary team decisions. Tumour lesions were manually segmented for reference and compared with predictions from the top-performing algorithm of the autoPET III challenge. Quantitative segmentation metrics were calculated, and lesion-level errors were assessed for impact on patient-level TNM and UICC staging.</p> Results <p>The algorithm achieved a mean Dice Similarity Coefficient (DSC) of 0.64. Lesion-level sensitivity was 95.8% across all patients, with a precision of 87.5%. False positive M-category lesions (<i>n</i> = 196) occurred as most frequent error. Of all false positives, 35.7% were benign and 34.7% non-oncologic pathologies. UICC staging matched ground truth in 207/306 patients, with most discordances due to upstaging (88/306).</p> Conclusion <p>Clinically driven metrics and cause-based error analysis offer valuable insight into AI segmentation performance. The evaluated model showed excellent lesion sensitivity but a tendency towards systematic overprediction across TNM categories. On a lesion level M-stage false positives and undersegmentation in the hilar region emerged as the main driver of clinically relevant upstaging. Despite promising lesion detection sensitivity, only 67.7% UICC-stagings&#xa0;were accurate using&#xa0;AI masks, indicating that diagnostic AI may support, though not yet replace, manual lesion evaluation in NSCLC [<sup>1</sup>⁸F]FDG PET/CT.</p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Artificial intelligence for TNM staging in NSCLC: a critical appraisal of segmentation utility in [1⁸F]FDG PET/CT

  • Maurice M. Heimer,
  • Jakob Dexl,
  • Johanna Ta,
  • Ricarda Ebner,
  • Felix L. Herr,
  • Leon Orasanin,
  • Katharina Jeblick,
  • Lisa C. Adams,
  • Lalith K. Shiyam Sundar,
  • Amanda Tufman,
  • Rudolf A. Werner,
  • Gabriel Sheikh,
  • Jens Ricke,
  • Michael Ingrisch,
  • Matthias P. Fabritius,
  • Clemens C. Cyran

摘要

Purpose

This study aims to investigate whether a diagnostic AI model can effectively support lesion detection and staging in non-small cell lung cancer (NSCLC) [1⁸F]FDG PET/CT studies, focusing on the distinction between technical segmentation accuracy and clinically meaningful performance.

Methods

In this retrospective single-centre study, [1⁸F]FDG PET/CT scans from 306 treatment-naïve NSCLC patients were reviewed with reference to multidisciplinary team decisions. Tumour lesions were manually segmented for reference and compared with predictions from the top-performing algorithm of the autoPET III challenge. Quantitative segmentation metrics were calculated, and lesion-level errors were assessed for impact on patient-level TNM and UICC staging.

Results

The algorithm achieved a mean Dice Similarity Coefficient (DSC) of 0.64. Lesion-level sensitivity was 95.8% across all patients, with a precision of 87.5%. False positive M-category lesions (n = 196) occurred as most frequent error. Of all false positives, 35.7% were benign and 34.7% non-oncologic pathologies. UICC staging matched ground truth in 207/306 patients, with most discordances due to upstaging (88/306).

Conclusion

Clinically driven metrics and cause-based error analysis offer valuable insight into AI segmentation performance. The evaluated model showed excellent lesion sensitivity but a tendency towards systematic overprediction across TNM categories. On a lesion level M-stage false positives and undersegmentation in the hilar region emerged as the main driver of clinically relevant upstaging. Despite promising lesion detection sensitivity, only 67.7% UICC-stagings were accurate using AI masks, indicating that diagnostic AI may support, though not yet replace, manual lesion evaluation in NSCLC [1⁸F]FDG PET/CT.