Deep learning-enhanced zero echo time MRI for glenohumeral assessment in shoulder instability: a comparative study with CT

  • Laura Carretero-Gómez,
  • Maggie Fung,
  • Florian Wiesinger,
  • Michael Carl,
  • Graeme McKinnon,
  • José de Arcos,
  • Sagar Mandava,
  • Santiago Arauz,
  • Eugenia Sánchez-Lacalle,
  • Satish Nagrani,
  • Juan Manuel López-Alcorocho,
  • Elena Rodríguez-Íñigo,
  • Norberto Malpica,
  • Mario Padrón

摘要

Purpose

To evaluate image quality and lesion conspicuity of zero echo time (ZTE) MRI reconstructed with deep learning (DL)-based algorithm versus conventional reconstruction and to assess DL ZTE performance against CT for bone loss measurements in shoulder instability.

Methods

Forty-four patients (9 females; 33.5 ± 15.65 years) with symptomatic anterior glenohumeral instability and no previous shoulder surgery underwent ZTE MRI and CT on the same day. ZTE images were reconstructed with conventional and DL methods and post-processed for CT-like contrast. Two musculoskeletal radiologists, blinded to the reconstruction method, independently evaluated 20 randomized MR ZTE datasets with and without DL-enhancement for perceived signal-to-noise ratio, resolution, and lesion conspicuity at humerus and glenoid using a 4-point Likert scale. Inter-reader reliability was assessed using weighted Cohen’s kappa (K). An ordinal logistic regression model analyzed Likert scores, with the reconstruction method (DL-enhanced vs. conventional) as the predictor. Glenoid track (GT) and Hill-Sachs interval (HSI) measurements were performed by another radiologist on both DL ZTE and CT datasets. Intermodal agreement was assessed through intraclass correlation coefficients (ICCs) and Bland–Altman analysis.

Results

DL ZTE MR bone images scored higher than conventional ZTE across all items, with significantly improved perceived resolution (odds ratio (OR) = 7.67, p = 0.01) and glenoid lesion conspicuity (OR = 25.12, p = 0.01), with substantial inter-rater agreement (K = 0.61 (0.38–0.83) to 0.77 (0.58–0.95)). Inter-modality assessment showed almost perfect agreement between DL ZTE MR and CT for all bone measurements (overall ICC = 0.99 (0.97–0.99)), with mean differences of 0.08 (− 0.80 to 0.96) mm for GT and − 0.07 (− 1.24 to 1.10) mm for HSI.

Conclusion

DL-based reconstruction enhances ZTE MRI quality for glenohumeral assessment, offering osseous evaluation and quantification equivalent to gold-standard CT, potentially simplifying preoperative workflow, and reducing CT radiation exposure.