Background <p>Derivo embolization device (DED) is a second-generation flow diverter (FD) that has been increasingly used in the management of intracranial aneurysms (IAs). DEDs consist of 48 nitinol wires with an inner platinum core and a blue-colored coating of oxides and oxynitrides, which mitigates these FDs’ thrombogenicity. This systematic review and meta-analysis evaluate the efficacy and safety of DED in IAs.</p> Methods <p>On February 25, 2025, a comprehensive search was conducted across PubMed, Embase, Scopus, and Web of Science in accordance with PRISMA guidelines. Studies reporting clinical and radiological outcomes of DED were included.</p> Results <p>Thirteen studies involving 1125 patients and 1338 aneurysms were included. The meta-analysis revealed a pooled complete occlusion rate of 83% (95% CI: 79%-87%), an adequate occlusion rate of 92% (95% CI: 84%-97%), and a favorable outcomes rate of 97% (95% CI: 92%-100%). Additionally, the meta-analysis demonstrated a pooled adjuvant coiling rate of 15% (95% CI: 7%-26%), a major ischemic complication rate of 1% (95% CI: 0%-2%), and a major hemorrhagic complication rate of 0% (95% CI: 0%-1%).</p> Conclusion <p>The current study’s findings revealed that DEDs are associated with promising complete and adequate occlusion rates concurrent with low rates of major ischemic and hemorrhagic complications.</p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Efficacy and safety of Derivo embolization device in intracranial aneurysms: A systematic review and Meta-Analysis

  • Bardia Hajikarimloo,
  • Salem M. Tos,
  • Abhishek Saha,
  • Ibrahim Mohammadzadeh,
  • Ali Mortezaei,
  • Rana Hashemi,
  • Dorsa Najari,
  • Azin Ebrahimi,
  • Adam A. Dmytriw,
  • Mohammad Amin Habibi

摘要

Background

Derivo embolization device (DED) is a second-generation flow diverter (FD) that has been increasingly used in the management of intracranial aneurysms (IAs). DEDs consist of 48 nitinol wires with an inner platinum core and a blue-colored coating of oxides and oxynitrides, which mitigates these FDs’ thrombogenicity. This systematic review and meta-analysis evaluate the efficacy and safety of DED in IAs.

Methods

On February 25, 2025, a comprehensive search was conducted across PubMed, Embase, Scopus, and Web of Science in accordance with PRISMA guidelines. Studies reporting clinical and radiological outcomes of DED were included.

Results

Thirteen studies involving 1125 patients and 1338 aneurysms were included. The meta-analysis revealed a pooled complete occlusion rate of 83% (95% CI: 79%-87%), an adequate occlusion rate of 92% (95% CI: 84%-97%), and a favorable outcomes rate of 97% (95% CI: 92%-100%). Additionally, the meta-analysis demonstrated a pooled adjuvant coiling rate of 15% (95% CI: 7%-26%), a major ischemic complication rate of 1% (95% CI: 0%-2%), and a major hemorrhagic complication rate of 0% (95% CI: 0%-1%).

Conclusion

The current study’s findings revealed that DEDs are associated with promising complete and adequate occlusion rates concurrent with low rates of major ischemic and hemorrhagic complications.