<p>An electrochemical sensor based on carboxylated multi-walled carbon nanotubes (c-MWCNT), Co<sub>3</sub>O<sub>4</sub> nanoparticles (Co<sub>3</sub>O<sub>4</sub>NP), and poly-<span>l</span>-valine (PolyVal) was fabricated for the simultaneous determination of hydroquinone (Hyd), catechol (Cat), and resorcinol (Res). The optimum amounts of modification materials on the electrode surface and the optimum pH of the working solution were determined to achieve the best electrode performance. Under optimum conditions, individual determination of each analyte was performed in the presence of other analytes. Simultaneous determination of Hyd, Cat, and Res was also carried out, and the performance characteristics of the electrode, such as working range, LOD, reusability, reproducibility, and selectivity, were evaluated for each analyte. In the simultaneous determination for Hyd, Cat, and Res, the linear working ranges were 5–260&#xa0;µM, 5–280&#xa0;µM, and 31–550&#xa0;µM, and the LOD values were 3.62&#xa0;µM, 2.57&#xa0;µM, and 7.97&#xa0;µM, respectively. The presented electrochemical sensor was successfully applied to the simultaneous determination of Hyd, Cat, and Res in tap water and river water, and satisfactory recovery values were obtained.</p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Simultaneous determination of hydroquinone, catechol, and resorcinol with an electrochemical sensor based on poly-l-valine, multi-walled carbon nanotubes, and Co3O4 nanoparticles

  • Noor Raad Abdulrasool,
  • İrem Okman Koçoğlu

摘要

An electrochemical sensor based on carboxylated multi-walled carbon nanotubes (c-MWCNT), Co3O4 nanoparticles (Co3O4NP), and poly-l-valine (PolyVal) was fabricated for the simultaneous determination of hydroquinone (Hyd), catechol (Cat), and resorcinol (Res). The optimum amounts of modification materials on the electrode surface and the optimum pH of the working solution were determined to achieve the best electrode performance. Under optimum conditions, individual determination of each analyte was performed in the presence of other analytes. Simultaneous determination of Hyd, Cat, and Res was also carried out, and the performance characteristics of the electrode, such as working range, LOD, reusability, reproducibility, and selectivity, were evaluated for each analyte. In the simultaneous determination for Hyd, Cat, and Res, the linear working ranges were 5–260 µM, 5–280 µM, and 31–550 µM, and the LOD values were 3.62 µM, 2.57 µM, and 7.97 µM, respectively. The presented electrochemical sensor was successfully applied to the simultaneous determination of Hyd, Cat, and Res in tap water and river water, and satisfactory recovery values were obtained.