A new hip fracture risk index derived from FEA-computed proximal femur fracture loads and energies-to-failure

  • Xuewei Cao,
  • Joyce H. Keyak,
  • Sigurdur Sigurdsson,
  • Chen Zhao,
  • Weihua Zhou,
  • Anqi Liu,
  • Thomas F. Lang,
  • Hong-Wen Deng,
  • Vilmundur Gudnason,
  • Qiuying Sha

摘要

Summary

Hip fracture risk assessment is an important but challenging task. Quantitative CT-based patient-specific finite element (FE) analysis (FEA) incorporates bone geometry and bone density in the proximal femur. We developed a global FEA-computed fracture risk index to increase the prediction accuracy of hip fracture incidence.

Purpose

Quantitative CT-based patient-specific finite element (FE) analysis (FEA) incorporates bone geometry and bone density in the proximal femur to compute the force (fracture load) and energy necessary to break the proximal femur in a particular loading condition. The fracture loads and energies-to-failure are individually associated with incident hip fracture, and provide different structural information about the proximal femur.

Methods

We used principal component analysis (PCA) to develop a global FEA-computed fracture risk index that incorporates the FEA-computed yield and ultimate failure loads and energies-to-failure in four loading conditions of 110 hip fracture subjects and 235 age- and sex-matched control subjects from the AGES-Reykjavik study. Using a logistic regression model, we compared the prediction performance for hip fracture based on the stratified resampling.

Results

We referred the first principal component (PC1) of the FE parameters as the global FEA-computed fracture risk index, which was the significant predictor of hip fracture (p-value < 0.001). The area under the receiver operating characteristic curve (AUC) using PC1 (0.776) was higher than that using all FE parameters combined (0.737) in the males (p-value < 0.001).

Conclusions

The global FEA-computed fracture risk index increased hip fracture risk prediction accuracy in males.