Purpose <p>The aim of this study was to assess whether norepinephrine at the time of extubation increases reintubation rates in critically ill patients with obesity.</p> Methods <p>The initial step was to analyze data that had been collected prospectively, using a retrospective approach—defined as the main cohort. Then, we validated our findings using data from a multicenter randomized-controlled trial (validation cohort). The primary objective was to compare reintubation within 7&#xa0;days, between patients with norepinephrine and without norepinephrine at the time of extubation. The secondary objective was to assess norepinephrine doses at extubation, normalized to body weight.</p> Results <p>Among the 3186 patients included in the main cohort, 837 had obesity. Among them, 213 (25%) were extubated with norepinephrine, with a median norepinephrine dose at extubation of 0.6&#xa0;mg/h of absolute value which corresponds to 0.097 (0.04–0.17) µg/kg/min of real body weight. No significant difference in reintubation rates was observed between patients extubated with norepinephrine (16%) and those without (17%, <i>p</i> = 0.85). Among the 656 patients with obesity in the validation cohort, we observed similar results, with a reintubation rate of 18% in those extubated with norepinephrine and 15% in those without (<i>p</i> = 0.45). Similar results were observed in the 2349 patients without obesity.</p> Interpretation <p>In critically ill patients with obesity, the use of norepinephrine at the time of extubation did not significantly increase the reintubation rates.</p> Clinical trial registration <p>NCT04014920 for the validation cohort.</p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Norepinephrine use at extubation in critically ill patients with obesity: a cohort study with multicenter validation

  • Audrey De Jong,
  • Mathieu Capdevila,
  • Yassir Aarab,
  • Francesca Rabboni,
  • Alina Kozoriz,
  • Guillaume Heupel,
  • Joris Pensier,
  • Ines Lakbar,
  • Clément Monet,
  • Gérald Chanques,
  • Samir Jaber

摘要

Purpose

The aim of this study was to assess whether norepinephrine at the time of extubation increases reintubation rates in critically ill patients with obesity.

Methods

The initial step was to analyze data that had been collected prospectively, using a retrospective approach—defined as the main cohort. Then, we validated our findings using data from a multicenter randomized-controlled trial (validation cohort). The primary objective was to compare reintubation within 7 days, between patients with norepinephrine and without norepinephrine at the time of extubation. The secondary objective was to assess norepinephrine doses at extubation, normalized to body weight.

Results

Among the 3186 patients included in the main cohort, 837 had obesity. Among them, 213 (25%) were extubated with norepinephrine, with a median norepinephrine dose at extubation of 0.6 mg/h of absolute value which corresponds to 0.097 (0.04–0.17) µg/kg/min of real body weight. No significant difference in reintubation rates was observed between patients extubated with norepinephrine (16%) and those without (17%, p = 0.85). Among the 656 patients with obesity in the validation cohort, we observed similar results, with a reintubation rate of 18% in those extubated with norepinephrine and 15% in those without (p = 0.45). Similar results were observed in the 2349 patients without obesity.

Interpretation

In critically ill patients with obesity, the use of norepinephrine at the time of extubation did not significantly increase the reintubation rates.

Clinical trial registration

NCT04014920 for the validation cohort.