Background <p>At 0.2% of all knee replacements implanted in Germany, patellofemoral joint arthroplasty (PFA) account for only a&#xa0;small proportion. However, the potential in the population appears to be significantly greater. In recent years, several robotic-assisted surgical procedures have been developed to increase precision in the implantation of endoprostheses.</p> Mako® system <p>At present, the Mako® system from Stryker is the only system that can implant an isolated patellofemoral joint replacement robotically. It can be used to analyze and adequately address complex anatomies such as trochlear dysplasia. The system provides support by simulating the positioning of the prosthesis and the exact execution of the plan by aligning the saw or reamer with haptic feedback.</p> Study situation <p>Studies on robotic-assisted PFA are rare but indicate improved precision with a&#xa0;robotic-assisted procedure. Despite that, an improved clinical and radiological outcome could not be demonstrated in a&#xa0;comparative study.</p> Outlook <p>A&#xa0;cost-benefit analysis should be discussed here, as should the necessary learning curve. In principle, robotic-assisted implantation of PFA appears to be a&#xa0;promising procedure. However, a&#xa0;superiority of this procedure over conventional methods cannot be postulated at the present time.</p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Robotik für den patellofemoralen Gelenkersatz – ein Fortschritt in der Endoprothetik?

  • Mara Hold,
  • Henning Windhagen,
  • Lars-Rene Tuecking

摘要

Background

At 0.2% of all knee replacements implanted in Germany, patellofemoral joint arthroplasty (PFA) account for only a small proportion. However, the potential in the population appears to be significantly greater. In recent years, several robotic-assisted surgical procedures have been developed to increase precision in the implantation of endoprostheses.

Mako® system

At present, the Mako® system from Stryker is the only system that can implant an isolated patellofemoral joint replacement robotically. It can be used to analyze and adequately address complex anatomies such as trochlear dysplasia. The system provides support by simulating the positioning of the prosthesis and the exact execution of the plan by aligning the saw or reamer with haptic feedback.

Study situation

Studies on robotic-assisted PFA are rare but indicate improved precision with a robotic-assisted procedure. Despite that, an improved clinical and radiological outcome could not be demonstrated in a comparative study.

Outlook

A cost-benefit analysis should be discussed here, as should the necessary learning curve. In principle, robotic-assisted implantation of PFA appears to be a promising procedure. However, a superiority of this procedure over conventional methods cannot be postulated at the present time.