Navigation und Robotik – status präsens und zukünftige Implikationen
摘要
Both navigation systems and robotics enable greater precision in the implantation of an artificial knee joint. However, they do not improve clinical outcomes. We hypothesized that although implantation of a total knee arthroplasty results in reconstruction of the alignment in the coronal plane, the variable rotational tibial and variable translational femoral and tibial component positioning lead to a change in the remaining alignment parameters of the lower extremity. However, these parameters could be determined using a navigation system or robot and could represent future implications for these systems.
MethodsThe kinematics and the position between femur and tibia before and after implantation of a total knee arthroplasty were determined using a navigation system in nine healthy knee joints of Thiel-fixed whole-body cadavers.
ResultsAfter arthroplasty, there was no change in the natural coronal alignment. In extension and the early degrees of flexion, the rotational position of the femur relative to the tibia was altered. This also led to a change in the positioning of the medial and lateral epicondyle in relation to the tibia; while both epicondyles were positioned more laterally in relation to the tibia after arthroplasty, the lateral epicondyle was significantly more lateral in relation to the tibia up to 20° of flexion.
DiscussionFollowing arthroplasty of a knee joint using the established technique, a good reconstruction of the coronal alignment was achieved with simultaneous changes in the alignment in both the rotational and translational directions between the femur and tibia. Using navigation as well as robotics, we would be able to quantify all alignment parameters and could achieve an alignment of the components or a reconstruction of the overall alignment in all six degrees of freedom. We might also be able to achieve a clinical advantage or increase the service life even further.