<p>We investigate the stability of topological charge under gradient flow taking the admissibility condition into account. For the SU(2) Wilson gauge theory with <i>β</i> = 2<i>.</i>45 and <i>L</i><sup>4</sup> = 12<sup>4</sup>, we numerically show that the gradient flows with the Iwasaki and DBW2 gauge actions stabilize the topological sectors significantly, and they have qualitatively different behaviors compared with the Wilson and tree-level Symanzik flows. By considering the classical continuum limit of the flow actions, we discuss that the coefficient of dimension-6 operators has to be positive for stabilizing the one-instanton configuration, and the Iwasaki and DBW2 actions satisfy this criterion while the Wilson and Symanzik actions do not. Moreover, we observe that the DBW2 flow stabilizes the topological sectors at the very early stage of the flow (<InlineEquation ID="IEq1"> <InlineMediaObject> <ImageObject Color="BlackWhite" FileRef="13130_2025_25997_Article_IEq1.gif" Format="GIF" Height="18" Rendition="HTML" Resolution="72" Type="Linedraw" Width="10" /> </InlineMediaObject> <EquationSource Format="MATHML"><math display="inline"> <mover accent="true"> <mi>t</mi> <mo stretchy="true">̂</mo> </mover> </math></EquationSource> <EquationSource Format="TEX">\( \hat{t} \)</EquationSource> </InlineEquation> ≈ 0<i>.</i>5–1), suggesting that a further systematic investigation of the DBW2 flow is warranted to confirm its computational efficiency in determining the gauge topology.</p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Lattice gradient flows (de-)stabilizing topological sectors

  • Yuya Tanizaki,
  • Akio Tomiya,
  • Hiromasa Watanabe

摘要

We investigate the stability of topological charge under gradient flow taking the admissibility condition into account. For the SU(2) Wilson gauge theory with β = 2.45 and L4 = 124, we numerically show that the gradient flows with the Iwasaki and DBW2 gauge actions stabilize the topological sectors significantly, and they have qualitatively different behaviors compared with the Wilson and tree-level Symanzik flows. By considering the classical continuum limit of the flow actions, we discuss that the coefficient of dimension-6 operators has to be positive for stabilizing the one-instanton configuration, and the Iwasaki and DBW2 actions satisfy this criterion while the Wilson and Symanzik actions do not. Moreover, we observe that the DBW2 flow stabilizes the topological sectors at the very early stage of the flow ( t ̂ \( \hat{t} \) ≈ 0.5–1), suggesting that a further systematic investigation of the DBW2 flow is warranted to confirm its computational efficiency in determining the gauge topology.